2001
DOI: 10.1063/1.1351829
|View full text |Cite
|
Sign up to set email alerts
|

Transient electrical discharges in small devices

Abstract: Fundamental and applied research on plasmas with high energy density that are unstable and radiate can be done at a relatively low cost with small plasma pinches. In this paper we discuss three experiments using small pinch devices: a capillary discharge, a Z-pinch driven by a small generator, and a low energy plasma focus. The experiments were complemented by magnetohydrodynamics numerical calculations in order to assist the design and physical interpretation of the experimental data. The diagnostics used in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
33
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(34 citation statements)
references
References 30 publications
1
33
0
Order By: Relevance
“…If the value of (I/a) is increased, speed will increase with (I/a), and T will increase with (I/a) 2 . In the present range of operation of plasma focus (∼ 1keV when is used D 2 ), increase in T will lead to increase in fusion cross section σv proportional to T ν , with ν ∼ 4, thus σv ∼ (I/a) 8 [23]. Thus in the limit, if a is keeping constant whilst increasing I, Y b−t ∝ I 3 and Y th ∝ I 8 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…If the value of (I/a) is increased, speed will increase with (I/a), and T will increase with (I/a) 2 . In the present range of operation of plasma focus (∼ 1keV when is used D 2 ), increase in T will lead to increase in fusion cross section σv proportional to T ν , with ν ∼ 4, thus σv ∼ (I/a) 8 [23]. Thus in the limit, if a is keeping constant whilst increasing I, Y b−t ∝ I 3 and Y th ∝ I 8 .…”
Section: Discussionmentioning
confidence: 99%
“…As first stage of a program to design a repetitive pulsed radiation generator for industrial applications we constructed two very small plasma focus operating at an energy level of the order of a) tens of joules (PF-50J, 160nF capacitor bank,20 − 35kV , 32 − 100J, ∼ 150ns time to peak current) [8][9][10] and b) hundred of joules (PF-400J, 880nF , 20 − 35kV , 176 − 539J, ∼ 300ns time to peak current) [11]. 2.1 Design criteria.…”
Section: Compact and Fast Plasma Foci Of Tens And Hundred Of Joules: mentioning
confidence: 99%
See 1 more Smart Citation
“…The detector is placed on the top of plasma chamber perpendicular to the axis of focus tube ( fig.2 no. 22) and is connected to a counter via an inverter, counting fusion neutrons with a calibration constant of 1.6 4 …”
Section: Experimental Results and Conclusionmentioning
confidence: 99%
“…Several successful attempts have been made to develop miniature and portable PF devices operated with bank energy in the ranges of tens to hundreds of joules. The pinching evidence has been observed in the PF devices operated at very low bank energies of 50 J, 6 50-70 J, 7 ≈100 J, 8 and 32-102 J, 9 leading to the generation of neutrons from a) E-mail: niranjan@barc.gov.in such devices. A battery (12 V DC, 400 Ah) powered transportable PF device working at 125 J of bank energy has been shown 10 to produce 10 5 to 10 6 neutrons/pulse but only in 30% of the PF discharges.…”
Section: Introductionmentioning
confidence: 97%