2013 IEEE Energy Conversion Congress and Exposition 2013
DOI: 10.1109/ecce.2013.6647307
|View full text |Cite
|
Sign up to set email alerts
|

Transient performance analysis of a small-scale PV-PHS power plant fed by a SVPWM drive applied for a distribution system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 11 publications
0
5
0
1
Order By: Relevance
“…The study demonstrated that the proposed model and optimization algorithm are effective and can be used for other similar studies in the future. Javanbakht et al [109] evaluated the transient performance of a small-scale plant consisting of a photovoltaic and a pumped hydroelectric storage system. The proposed system included two six-pulse converters interconnected through a DC link, to which the PV plant was interfaced via a single-stage bidirectional boost converter.…”
Section: Solar Photovoltaic Pumped Hydroelectric Energy Storage (Pv-pmentioning
confidence: 99%
“…The study demonstrated that the proposed model and optimization algorithm are effective and can be used for other similar studies in the future. Javanbakht et al [109] evaluated the transient performance of a small-scale plant consisting of a photovoltaic and a pumped hydroelectric storage system. The proposed system included two six-pulse converters interconnected through a DC link, to which the PV plant was interfaced via a single-stage bidirectional boost converter.…”
Section: Solar Photovoltaic Pumped Hydroelectric Energy Storage (Pv-pmentioning
confidence: 99%
“…A number of authors have analyzed the role of PHS on RES price mechanisms and economic aspects of electricity markets [7,[10][11][12][13][14][15][16][17][18][19], while others have studied the technical aspects of implementation and energy contribution of PHS systems [8,[20][21][22][23][24][25][26]. In addition, many authors have developed CBA on the subject of RES [27][28][29][30][31][32][33][34][35][36][37][38][39][40][41][42].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Despite some environmental drawbacks of hydropower, its added value as a storage system, which is even more necessary in the current global energy transition, has ignited renewed interest in the technology leading to rehabilitation of old hydropower systems and development of new systems as an economically and technically viable option to support volatile solar and wind resources [8]. Several studies have explored the feasibility of such hydro-wind [9,10,11,12], hydro-solar [13,14,15,16,17,18] and hydro-wind-solar [19] systems.…”
Section: Introductionmentioning
confidence: 99%