2019
DOI: 10.1016/j.dental.2018.11.033
|View full text |Cite
|
Sign up to set email alerts
|

Translational research on clinically failed zirconia implants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
41
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(44 citation statements)
references
References 40 publications
3
41
0
Order By: Relevance
“…The tetragonal to monoclinic phase transformation is known to induce shear through micro-scale twinning [58,59] and TEM studies of interfaces within YPSZ solid oxide fuel cells have shown very similar features at locations where the tetragonal to monoclinic phase transformation is induced [60,61]. This highly localised transformation is characteristic of a boundary level effect which is similar to those observed at other interfaces within the literature [62,63].…”
Section: Monoclinic Ypsz Phase Distributionsupporting
confidence: 62%
“…The tetragonal to monoclinic phase transformation is known to induce shear through micro-scale twinning [58,59] and TEM studies of interfaces within YPSZ solid oxide fuel cells have shown very similar features at locations where the tetragonal to monoclinic phase transformation is induced [60,61]. This highly localised transformation is characteristic of a boundary level effect which is similar to those observed at other interfaces within the literature [62,63].…”
Section: Monoclinic Ypsz Phase Distributionsupporting
confidence: 62%
“…Yet, reliable mechanical characterization, especially by means of fracture toughness (KIc) testing, is still in shortage [6]. More so for new, high-yttria content 'translucent' zirconias, despite the explosive trend of prescribing zirconias as monolithic constructs in clinical dentistry [9]. Dental zirconias are mostly delivered as intermediate pre-sintered "white-bodies", produced by powder compaction and long duration sintering at low-temperatures (900-1000 °C), i.e.…”
Section: Introductionmentioning
confidence: 99%
“…Both studies agreed that the diameter-reduced implants of less than 3.6 mm were not suitable for clinical use [22]. Consequently, a modified design of 3.6 mm has now been introduced, with its application limited to the anterior incisor region of both maxillary and mandibular dentition [22].…”
Section: Discussionmentioning
confidence: 93%
“…The eligible articles were all in vivo or ex vivo studies, with one study categorized as a Randomized Control Trial (Paolantoni, et al) [ 20 ] whilst the remaining two were both Cohort studies (Roehling and Scherrer, et al) [ 21 , 22 ]. Classifying the included articles based on their study designs allowed for adequate analysis of the fracture resistance in one- and two-piece zirconia implants placed within the anterior region.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation