2020
DOI: 10.1007/s42835-020-00468-9
|View full text |Cite
|
Sign up to set email alerts
|

Transmission Security Enhancement under (N−1) Contingency Conditions with Optimal Unified Power Flow Controller and Renewable Energy Sources Generation

Abstract: Introduction Transmission system security management under (N−1) line contingency is one of the typical and essential tasks in power system operation and control. This paper examines the impact of the optimal unified power flow controller (OUPFC) and renewable energy sources (RES) on the severity of (n−1) line contingency on transmission system security. Materials and methods To test the performance of OUPFC device under single line contingency conditions, an optimal power flow (OPF) based multi-objective func… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
12
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 38 publications
0
12
0
Order By: Relevance
“…The optimal parameters setting OUPFC has been determined for transient stability of the system [24]. The placement and rating of the OUPFC has been assigned for power loss reduction and line collapse proximity indicator [25]. Enforcement the operating constrains is based on alleviating the specified values which are controlled by the FACTS.…”
Section: Introduction a Literature Surveymentioning
confidence: 99%
See 2 more Smart Citations
“…The optimal parameters setting OUPFC has been determined for transient stability of the system [24]. The placement and rating of the OUPFC has been assigned for power loss reduction and line collapse proximity indicator [25]. Enforcement the operating constrains is based on alleviating the specified values which are controlled by the FACTS.…”
Section: Introduction a Literature Surveymentioning
confidence: 99%
“…It should be highlighted here that handling the constraints at their maximum values to maximize the utilization of the used controller. The OUPFC is an efficient controller consists of a phase shifting transformer combined with a UPFC [22,23,25,26]. Thus, the OUPFC is a combined series shunt controller, and it has ability to control the active and reactive power flow in TL.…”
Section: Introduction a Literature Surveymentioning
confidence: 99%
See 1 more Smart Citation
“…Sensitivity analysis was used for optimal location of TAST/UPFC in this reference. The optimal allocation of UPFC to security management under (N − 1) line contingency is presented in Reference 48. Line collapse proximity indicator (LCPI) is considered as security index.…”
Section: Introductionmentioning
confidence: 99%
“…The economic operation is performed in power systems to analyze the effect of OUPFC under weather changing conditions as well as variable loading conditions [23]. Transmission system security is enhanced under single line contingency conditions with OUPFC device under different renewable energy generations and is proposed in [24].…”
mentioning
confidence: 99%