2018
DOI: 10.1111/jon.12528
|View full text |Cite
|
Sign up to set email alerts
|

Transorbital Sonography for Early Prognostication of Hypoxic‐Ischemic Encephalopathy After Cardiac Arrest

Abstract: Early and reliable prognostication of outcomes in patients with HIE can be simplified by ONSD values gathered with the use of TOS. Main advantages compared to other established markers are prognostication within the first 24 hours and independence from therapy with hypothermia. A higher level of accuracy can be reached by combining computed tomography (gray-to-white matter ratio values) and ONSD values.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
39
2

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 33 publications
(43 citation statements)
references
References 18 publications
2
39
2
Order By: Relevance
“…This is the first metanalysis of normal OND and ONSD assessed by TOS, reporting a mean OND of 3.08 mm (95% CI, 2.9‐3.25) and a mean ONSD value was 4.78 mm (95% CI, 4.63‐4.94) across all eligible studies. In the recent years, TOS became increasingly established as a fast, noninvasive, and easy repeatable technique in several neurological diseases, particularly with alteration of intracranial pressure . With regard to the technical implementation of the analyzed studies, a consistent acquisition of the measured values 3 mm behind the optic disc was found.…”
Section: Discussionmentioning
confidence: 85%
See 4 more Smart Citations
“…This is the first metanalysis of normal OND and ONSD assessed by TOS, reporting a mean OND of 3.08 mm (95% CI, 2.9‐3.25) and a mean ONSD value was 4.78 mm (95% CI, 4.63‐4.94) across all eligible studies. In the recent years, TOS became increasingly established as a fast, noninvasive, and easy repeatable technique in several neurological diseases, particularly with alteration of intracranial pressure . With regard to the technical implementation of the analyzed studies, a consistent acquisition of the measured values 3 mm behind the optic disc was found.…”
Section: Discussionmentioning
confidence: 85%
“…The interrater reliability has been shown to be very high in several studies, so that for trained examiners no relevant variability effect on the measured values should occur. In over two thirds of the evaluated studies, authors used the mean value from three subsequent measurements to reduce further the effect of intrarater variability.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations