2008
DOI: 10.1080/00313020802198101
|View full text |Cite
|
Sign up to set email alerts
|

TRARESA: a tissue microarray-based hospital system for biomarker validation and discovery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
10

Relationship

8
2

Authors

Journals

citations
Cited by 21 publications
(18 citation statements)
references
References 50 publications
0
18
0
Order By: Relevance
“…Three sets of ovarian cancer tissue microarrays containing three cores from 198 primary ovarian cancer cases, three sets of breast tissue microarrays containing three cores from 300 breast cancer cases, and one set of gastric tissue mircroarrays containing 142 gastric cancer cases were constructed as detailed in previous studies. 18,19 A 1.0-mm-diameter needle was used to punch a donor core from morphologically representative areas of a donor tissue block. The core was subsequently inserted into a recipient paraffin block using a MTA-1 Manual Tissue Arrayer (Beecher Instruments, WI).…”
Section: Methodsmentioning
confidence: 99%
“…Three sets of ovarian cancer tissue microarrays containing three cores from 198 primary ovarian cancer cases, three sets of breast tissue microarrays containing three cores from 300 breast cancer cases, and one set of gastric tissue mircroarrays containing 142 gastric cancer cases were constructed as detailed in previous studies. 18,19 A 1.0-mm-diameter needle was used to punch a donor core from morphologically representative areas of a donor tissue block. The core was subsequently inserted into a recipient paraffin block using a MTA-1 Manual Tissue Arrayer (Beecher Instruments, WI).…”
Section: Methodsmentioning
confidence: 99%
“…18,19 Briefly, a needle with 0.6-mm diameter was used to punch a donor core from morphologically representative areas of a donor tissue block. The core was subsequently inserted into a recipient paraffin block using an ATA-100 tissue arrayer (Chemicon, USA).…”
Section: Tissue Microarraysmentioning
confidence: 99%
“…Immunohistochemistry was performed on TMA constructed from formalin-fixed paraffin-embedded (FFPE) prostate tumors and matched benign tissues following the protocol described previously (Zhang et al 2003, Salto-Tellez et al 2007, Das et al 2008b. Sections (4 mm) were deparaffinized and rehydrated using graded alcohols before heating with antigen retrieval solution (pH 6) at 120 8C for 5 min, followed by peroxidase blocking for 10 min at room temperature.…”
Section: Immunohistochemistrymentioning
confidence: 99%