OBJECTIVES
This study aimed to evaluate the efficacy and safety of a handmade fenestrated stent graft over an aortic stent graft for preserving the left subclavian artery (LSA) in thoracic endovascular aortic repair (TEVAR).
METHODS
From July 2015 to October 2018, a total of 32 consecutive patients with various thoracic aortic pathologies who underwent TEVAR in which handmade fenestration over a thoracic aortic stent graft was used for LSA were included. Outcomes including technical success, procedure-related complications, perioperative mortality and morbidity and graft patency were analysed.
RESULTS
Twenty-four patients (75.00%) presented with aortic dissection, 5 patients (15.63%) with thoracic aortic aneurysm and 2 patients (6.25%) with penetrating aortic ulcer; 1 patient (3.13%) required re-TEVAR due to endoleak and sac expansion from previous TEVAR for thoraco-abdominal aneurysm. TEVAR was performed in a zone 2 landing with single fenestration for LSA (26 patients, 81.25%), zone 1 landing with double fenestration for both LSA and left common carotid artery (5 patients, 15.63%) or zone 1 landing with single fenestration for LSA and a chimney graft for left common carotid artery (1 patient, 3.13%). The technical success rate, defined as the successful alignment of fenestration to LSA, was 93.75%. At a mean follow-up of 17.3 months, 4 cases of endoleak and 2 cases of stent graft-induced new entry were noted, 3 of which were treated endovascularly.
CONCLUSIONS
Our preliminary results demonstrate the viability of preserving LSA blood flow in TEVAR using a handmade stent graft fenestration to treat various aortic pathologies in various clinical situations and the technical feasibility and short-term results that may justify the use of this method in emergency cases.