2011
DOI: 10.1016/j.archoralbio.2011.05.014
|View full text |Cite
|
Sign up to set email alerts
|

Tri-phasic modulation of ACh- and NA-maintained calcium plateau by high potassium in isolated mouse submandibular granular convoluted tubular cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 45 publications
0
2
0
Order By: Relevance
“…AR4-2J cells were cultured on glass cover-slips for 2 days; the cell-attached cover-slips were assembled in Sykes-Moore chambers before AR4-2J cells were loaded with Fura-2 AM (10 μM, 60 min) and perifused at 1 mL·min −1 . Fluorescent calcium imaging was done as reported previously [6,44,47,48] in a Photon Technology International (PTI, Ediosn, N.J., USA) calcium measurement system, with a photon-counting PMT (PTI PMT814) or a CCD (NEO-5.5-CL-3, Andor) as detector, in an inverted fluorescent microscope (Olympus IX or Nikon NE 300), with fluorescence collected at 510 ± 25 nm. The fluorescent ratios of F 340 /F 380 were shown as indications of calcium concentrations and were plotted against time with SigmaPlot as before [6,47,49].…”
Section: Methodsmentioning
confidence: 99%
“…AR4-2J cells were cultured on glass cover-slips for 2 days; the cell-attached cover-slips were assembled in Sykes-Moore chambers before AR4-2J cells were loaded with Fura-2 AM (10 μM, 60 min) and perifused at 1 mL·min −1 . Fluorescent calcium imaging was done as reported previously [6,44,47,48] in a Photon Technology International (PTI, Ediosn, N.J., USA) calcium measurement system, with a photon-counting PMT (PTI PMT814) or a CCD (NEO-5.5-CL-3, Andor) as detector, in an inverted fluorescent microscope (Olympus IX or Nikon NE 300), with fluorescence collected at 510 ± 25 nm. The fluorescent ratios of F 340 /F 380 were shown as indications of calcium concentrations and were plotted against time with SigmaPlot as before [6,47,49].…”
Section: Methodsmentioning
confidence: 99%
“…Emission (dichroic mirror 400DCLP, emitter D510/40 nm) was detected with a PMT (pmt814, PTI) or a CCD (NEO-5.5-CL-3, Andor). Calcium concentration was expressed as F 340 /F 380 and plotted against time with SigmaPlot as reported before ( Jia and Cui, 2011 ; Liang et al, 2013 ; Li et al, 2015 ).…”
Section: Methodsmentioning
confidence: 99%