2015
DOI: 10.1371/journal.pone.0142190
|View full text |Cite
|
Sign up to set email alerts
|

Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy

Abstract: BackgroundBevacizumab is an exogenous inhibitor which inhibits the biological activity of human VEGF. Several studies have investigated the effectiveness of bevacizumab therapy according to different cancer types but these days there is an intense debate on its utility. We have investigated different methods to find the best tumor volume estimation since it creates the possibility for precise and effective drug administration with a much lower dose than in the protocol.Materials and MethodsWe have examined C38… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
107
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 126 publications
(109 citation statements)
references
References 39 publications
1
107
0
1
Order By: Relevance
“…In the case group, mice received 1/18 mg/kg injection each day starting from the third day for 18 days. The tumor volumes were measured with calipers and MRI, the calculation of tumor volume based on these measurements and more details of the experiment can be found in [13], [16]. The parametric identification was done by utilizing the measurement from the control group, while validation of the model was done using the measurements from the case group.…”
Section: Parametric Identification Of the Model Using Least Squamentioning
confidence: 99%
See 1 more Smart Citation
“…In the case group, mice received 1/18 mg/kg injection each day starting from the third day for 18 days. The tumor volumes were measured with calipers and MRI, the calculation of tumor volume based on these measurements and more details of the experiment can be found in [13], [16]. The parametric identification was done by utilizing the measurement from the control group, while validation of the model was done using the measurements from the case group.…”
Section: Parametric Identification Of the Model Using Least Squamentioning
confidence: 99%
“…The parametric identification of the model is done using measurements from C57Bl/6 mice experiments, where the mice were implanted subcutaneously with C38 colon adenocarcinoma, and received treatment with bevacizumab [13]. The mice were separated into a control group and a case group.…”
Section: Introductionmentioning
confidence: 99%
“…The third dimension should be estimated, and assuming a certain shape, tumor volume can be approximated. Based on different estimation methods, we obtained three different tumor volume values for each measurement point [14]. Measurements with caliper were made on the 0th, 2nd, 4th, 6th, 8th, 10th, 12th, 14th, 16th, 18th and 19th days of the experiment.…”
Section: Tumor Volume Measurementmentioning
confidence: 99%
“…However, with the current scientific knowledge, there is no medical device which can handle continuous infusion cancer therapy [18]; hence we designed a discretetime control herein.…”
Section: Background Of the Control Problemmentioning
confidence: 99%