2004
DOI: 10.1016/j.echo.2004.06.019
|View full text |Cite
|
Sign up to set email alerts
|

Two-dimensional strain–a novel software for real-time quantitative echocardiographic assessment of myocardial function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

17
797
1
34

Year Published

2007
2007
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 1,074 publications
(849 citation statements)
references
References 17 publications
17
797
1
34
Order By: Relevance
“…The methods for image acquisition and postprocessing of GLS with speckle tracking have been described (Leitman et al. 2004). Briefly, the apical three‐, two‐, and four‐chamber high frame rate grayscale acquisitions (40–80 frames/sec) were obtained.…”
Section: Methodsmentioning
confidence: 99%
“…The methods for image acquisition and postprocessing of GLS with speckle tracking have been described (Leitman et al. 2004). Briefly, the apical three‐, two‐, and four‐chamber high frame rate grayscale acquisitions (40–80 frames/sec) were obtained.…”
Section: Methodsmentioning
confidence: 99%
“…The software then automatically detected frame-to-frame movement of the natural ultrasound reflections (speckles) on standard ultrasonic images in two dimensions based on the block-matching and autocorrelation search algorithms. 3 The carotid arterial wall was equally divided into six segments, and each segment was analyzed individually. CS, which is expressed as the circumferential stretch during systole, was automatically determined from each time-strain curve for all six segments.…”
Section: The Measurement Of Csmentioning
confidence: 99%
“…[3][4][5][6][7][8][9] Although this method can be applied to the human carotid arterial wall to directly assess arterial elasticity, it has not been well assessed. Therefore, the aims of this study were to evaluate the feasibility of direct measurement of peak circumferential strain (CS) of the carotid arterial wall using 2DST, to compare the reproducibility of CS with conventional arterial stiffness parameters in healthy subjects, and to compare CS between subjects with and without hypertension.…”
Section: Introductionmentioning
confidence: 99%
“…5a, 5b). Strain imaging is derived from TDI 49 and more recently from 2D myocardial speckle‐tracking 50 . Unlike TDI measurements, S and SR are not subjected to cardiac tethering 51 , 52 .…”
Section: Newer Parameters and Applicationmentioning
confidence: 99%