2014
DOI: 10.1016/j.chroma.2014.02.052
|View full text |Cite
|
Sign up to set email alerts
|

Two novel solvent system compositions for protected synthetic peptide purification by centrifugal partition chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 27 publications
0
4
0
Order By: Relevance
“…CPC processing is based on the solutes separated in different distribution coefficients ( Kd ) between two immiscible solvent systems and the ratio of solvent system is adjusted to get the Kd value of target analyte between 0.5 and 2.0 [ 33 ]. In this study, the Kd values of TC and cis -crocetin were performed in four solvent systems as shown in the Table 4 .…”
Section: Resultsmentioning
confidence: 99%
“…CPC processing is based on the solutes separated in different distribution coefficients ( Kd ) between two immiscible solvent systems and the ratio of solvent system is adjusted to get the Kd value of target analyte between 0.5 and 2.0 [ 33 ]. In this study, the Kd values of TC and cis -crocetin were performed in four solvent systems as shown in the Table 4 .…”
Section: Resultsmentioning
confidence: 99%
“…As for now, two most popular scales of biphasic solvent systems are as follows: The ARIZONA systems range (or HEMWat), composed of heptane (or hexane), ethyl acetate, methanol, and water, with the modification as OKA scale, with n ‐butanol as a fifth solvent (also called “extended ARIZONA”). The acetone scale composed of heptane, toluene, acetone, and water . Two novel solvent system compositions for protected synthetic peptide purification by CPC were proposed by Amarouche et al. . Protected synthetic peptide intermediates are often hydrophobic and not soluble in most common solvents.…”
Section: Improvements and Modifications Of The Centrifugal Partition mentioning
confidence: 99%
“…Two novel solvent system compositions for protected synthetic peptide purification by CPC were proposed by Amarouche et al. . Protected synthetic peptide intermediates are often hydrophobic and not soluble in most common solvents.…”
Section: Improvements and Modifications Of The Centrifugal Partition mentioning
confidence: 99%
“…CPC has two main elution modes: descending mode where the less dense “upper” phase is stationary and the denser “lower” phase is pumped through it, and ascending mode where the lower phase is stationary and the upper phase is pumped through it . CPC has been utilized for many separations including that of natural products, proteins and peptides, and most recently for the enantioseparation of chiral compounds …”
Section: Introductionmentioning
confidence: 99%