1998
DOI: 10.1016/s0021-9673(98)00041-7
|View full text |Cite
|
Sign up to set email alerts
|

Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
42
0
2

Year Published

1999
1999
2013
2013

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 52 publications
(44 citation statements)
references
References 12 publications
0
42
0
2
Order By: Relevance
“…Sorbent traps present the advantages that they can be prepared on a micro-scale and coupled on-line with a GC system to allow near real-time measurements [97][98][99][100][101], and the sorbent configuration can be easily changed to adapt to different compounds.…”
Section: Concentration On Solid Sorbentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Sorbent traps present the advantages that they can be prepared on a micro-scale and coupled on-line with a GC system to allow near real-time measurements [97][98][99][100][101], and the sorbent configuration can be easily changed to adapt to different compounds.…”
Section: Concentration On Solid Sorbentsmentioning
confidence: 99%
“…However, the wide range of VOCs present in breath results in no single sorbent being capable of adsorbing all the compounds present in breath samples, so a multicomponent sorbent is necessary to complete screening and determination [25,44,64,[95][96][97]100,101].…”
Section: Concentration On Solid Sorbentsmentioning
confidence: 99%
“…Second, the use of a cryotrap increases the complexity of the 10 instrumentation and makes it necessary to use cryogenic gases, which complicates the development of portable instruments based on this configuration. It has been demonstrated that it is possible to develop miniaturized TD modules without the use of cryogenic traps, which allow the direct injection of the retained VOCs in the multibed trap into a GC column [17,20,21]. When using this simplified configuration, the formation of artifacts due to thermal oxidation reactions in the surface of the sorbents is reduced and more reproducible results can be obtained [20].…”
Section: Microtrap Evaluationmentioning
confidence: 99%
“…Feng and Mitra [21] showed that the greater the internal diameter of the adsorbent microtrap, the greater the bandwidth of the desorbed compounds. However, the use of small-internal diameter traps has the disadvantage that there is an increase in the pressure drop along the trap, which decreases the sampling flow rate.…”
Section: Microtrap Evaluationmentioning
confidence: 99%
“…VOC's são normalmente analisados por cromatografia gasosa e podem fazer uso de pré-concentradores [39]. Sistemas pequenos de adsorção já foram reportados [40,41] e atualmente estão sendo miniaturizados [42]. Zellers et al [43] propôs a construção de um micro cromatógrafo (µCG) para a determinação de 30-50 tipos distintos de vapores, misturados em ppb (partes por bilhão) [44], e adsorção em esferas de grafite [45, 46, 47,].…”
Section: Separação De Componentes: Cromatógrafos E/ou Dispositivos MIunclassified