Type testing a new personnel dosimetry system to IEC 62387

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…For both operational dosimetry quantities, H p (10) and H p (0.07), it can be concluded that D2 shows improvement in terms of relative energy response, which is important for its use in low-energy photon fields similar to N-40. The comparison of energy dependence of D1 and D2 with the results presented in the research by Luo et al (2017) showed that LiF:Mg,Cu,P material placed in holder 8850 has a less pronounced energy dependence for the low energy photons, with the maximum values not greater than 20%.…”
Section: Energy Responsementioning
confidence: 55%
See 3 more Smart Citations
“…For both operational dosimetry quantities, H p (10) and H p (0.07), it can be concluded that D2 shows improvement in terms of relative energy response, which is important for its use in low-energy photon fields similar to N-40. The comparison of energy dependence of D1 and D2 with the results presented in the research by Luo et al (2017) showed that LiF:Mg,Cu,P material placed in holder 8850 has a less pronounced energy dependence for the low energy photons, with the maximum values not greater than 20%.…”
Section: Energy Responsementioning
confidence: 55%
“…Previous research shows that LiF:Mg,Cu,P has a smaller change in energy and angular response (N-40, 60°) under irradiation conditions—up to +17 % for H p (10) (Luo et al 2017). If only angular dependence is considered, change in relative response is similar for LiF:Mg,Cu,P and D1 [approximately 35% increase from (N-40, 0°)].…”
Section: Resultsmentioning
confidence: 92%
See 2 more Smart Citations
“…cesium-137 (IG-13) and cobalt-60 point sources were used for higher photon energies exposures. All the irradiations were carried out by Air Kerma with the standard procedure mentioned in IEC 62387, [35,36] at room temperature at Secondary Standards Dosimetry Laboratory (SSDL), PINSTECH, Islamabad Pakistan, to obtain a consistent reference condition at a known dose. A standard test dose of 500 mGy was used for studying the various properties of the samples as further described.…”
Section: Sample Irradiation and Readoutmentioning
confidence: 99%