2011
DOI: 10.1016/j.ymgme.2010.08.018
|View full text |Cite
|
Sign up to set email alerts
|

Ultra fast and sensitive liquid chromatography tandem mass spectrometry based assay for galactose-1-phosphate uridylyltransferase and galactokinase deficiencies

Abstract: The diagnosis of transferase and galactokinase deficiency galactosemia usually involves the measurement of erythrocyte galactose-1-phosphate uridylyltransferase (GALT) and galactokinase (GALK) enzyme activity, respectively. The current gold standard assays for these enzymes are radioactive assays, which are laborious and/or incapable of measuring low enzyme activities. To further our knowledge of genotype-phenotype relationships, we had developed an assay for GALT activity alone using LC-MS/MS. In this study w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
18
0
2

Year Published

2013
2013
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(25 citation statements)
references
References 15 publications
2
18
0
2
Order By: Relevance
“…Using the LC-MS/MS procedure published by Li et al, 26 we confirmed the total absence of GALT activity in the homozygous GalT genetrapped mice (Figure 1b). Also, the homozygous GalT gene-trapped mice accumulated up to 60.8±27.3 mM of gal-1P in RBC even when they were unchallenged (ie, fed with normal chow; Figure 1c).…”
Section: Biochemical Phenotypes Of the New Galt Gene-trapped Mouse Modelsupporting
confidence: 74%
See 2 more Smart Citations
“…Using the LC-MS/MS procedure published by Li et al, 26 we confirmed the total absence of GALT activity in the homozygous GalT genetrapped mice (Figure 1b). Also, the homozygous GalT gene-trapped mice accumulated up to 60.8±27.3 mM of gal-1P in RBC even when they were unchallenged (ie, fed with normal chow; Figure 1c).…”
Section: Biochemical Phenotypes Of the New Galt Gene-trapped Mouse Modelsupporting
confidence: 74%
“…8 GALT activity was determined according to procedure published by Li et al, 26 which used a direct method with LC-MS/MS detection of the product of the reaction. Waters XBridge BEH amide column (2.1 mm  100 mm, 3.5 mm) and AB Sciex API 4000 system (AB Sciex IS, Framingham, MA, USA) equipped with Shimadzu LC units was used in this study.…”
Section: Biochemical Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…43,44 These methods can be multiplexed and allow the simultaneous determination of enzyme activity for all three galactosemia types with minimal sample volume. This represents a significant improvement for diagnostic testing.…”
Section: Galt Assaysmentioning
confidence: 99%
“…Recently, LC-MS/MS methods have been developed to measure GALK and GALE activity in RBCs and/or DBS using 13 C-labeled substrate. [43][44][45] Metabolite assays…”
Section: Galk and Gale Assaysmentioning
confidence: 99%