2016
DOI: 10.1007/s00604-016-1790-y
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-high performance liquid chromatography combined with mass spectrometry for determination of aflatoxins using dummy molecularly imprinted polymers deposited on silica-coated magnetic nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
17
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 56 publications
(17 citation statements)
references
References 33 publications
0
17
0
Order By: Relevance
“…The best extraction conditions involved using 80 mg of sorbent to achieve the extraction of aflatoxins from corn samples, obtaining recovery values ranging from 75 to 99%. Tan et al also developed a magnetic dummy MIP for the determination of aflatoxins from corn and tea leaves [73]. In this case, the magnetic core was of Fe 3 O 4 which was first coated with silica and afterwards the silanol groups of the silica surface were modified with the MIP.…”
Section: Micro-magnetic Solid-phase Extraction (µ-Mspe)mentioning
confidence: 99%
“…The best extraction conditions involved using 80 mg of sorbent to achieve the extraction of aflatoxins from corn samples, obtaining recovery values ranging from 75 to 99%. Tan et al also developed a magnetic dummy MIP for the determination of aflatoxins from corn and tea leaves [73]. In this case, the magnetic core was of Fe 3 O 4 which was first coated with silica and afterwards the silanol groups of the silica surface were modified with the MIP.…”
Section: Micro-magnetic Solid-phase Extraction (µ-Mspe)mentioning
confidence: 99%
“…Four milliliters (10 μg/mL) AFB1 solution (prepared in methanol-water) was added into the tubes. The mixture was vigorously shaken at 2500 rpm for a series of time (1,2,3,6,9,12,15,20,25,30,35,40, and 60 min). The tubes were centrifuged and the supernatants were measured by HPLC.…”
Section: Dynamics Of Polymersmentioning
confidence: 99%
“…Tan et al [11] discovered that the MIP they had prepared using 5,7-dimethoxycoumarin as a dummy template showed high adsorption capability for four aflatoxins (aflatoxins B1, B2, G1 and G2), and also showed that the rebinding capacity of the MIPs to the aflatoxins is much better than to three other mycotoxins. On the other hand, their NIPs did not exhibit an obvious difference in rebinding capacity between aflatoxins and other mycotoxins.…”
Section: Selectivity Of the Mipmentioning
confidence: 99%
“…Analytical techniques like gas chromatography (GC) or gas chromatography tandem mass spectrometry (GC-MS) have also traditionally been employed for aflatoxin analysis. However, HPLC-MS/ MS has become the technique of choice due its ability to rapidly analyze a more diverse set of analytes with better sensitivity [11]. These methods, however, lack direct application to food samples because the contaminants are present at very low concentrations in highly complex and morphologically structured matrices [12].…”
mentioning
confidence: 99%
See 1 more Smart Citation