2017
DOI: 10.1007/s11664-017-5573-y
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive Determination of Piroxicam at Diflunisal-Derived Gold Nanoparticle-Modified Glassy Carbon Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(13 citation statements)
references
References 25 publications
3
10
0
Order By: Relevance
“…Moreover, SWV did not show cathodic peaks with significant difference from the blank assays ( Figure 2B). PRX seems to have an irreversible electrooxidation reaction in acidic pHs (I pa /I pc > 1.0), as presented in previous studies and in the SWV herein conducted (Shaikh et al, 2017;Torriero et al, 2006).…”
Section: Results and Discussion Electrochemical Performance Of Pgesupporting
confidence: 81%
See 1 more Smart Citation
“…Moreover, SWV did not show cathodic peaks with significant difference from the blank assays ( Figure 2B). PRX seems to have an irreversible electrooxidation reaction in acidic pHs (I pa /I pc > 1.0), as presented in previous studies and in the SWV herein conducted (Shaikh et al, 2017;Torriero et al, 2006).…”
Section: Results and Discussion Electrochemical Performance Of Pgesupporting
confidence: 81%
“…In literature, the determination of PRX with the use of many modified electrodes is reported. Some of these modified electrodes show high sensibility with LOD and LOQ values of nM scale (10 -9 mol.L -1 ), however, the preparation of these electrodes require specific materials, expensive equipment, qualified instrumentalists and are often strenuous (Shahrokhian, Jokar, Ghalkhani, 2010;Macêdo, 2018;Gholivand, Malekzadeh, Derakhshan, 2014;Shaikh et al, 2017).…”
Section: Introductionmentioning
confidence: 99%
“…The proposed method was sensitive and accurate with mean recovery values for the different pharmaceutical formulations of 98.7% and all method validation parameters within the specified limits [64]. Under the optimized conditions methods showed good linearity in the concentration ranges 8x10 -8 -4x10 -6 M, 3x10 -8 -5x10 -7 M and 5x10 -9 -2x10 -7 for 60s, 180s and 300s, respectively [64] and 0.5-50 µM [65] with obtained correlation coefficients over 0.996 [64]. The achieved LOD values were 0.375 ng/ml for MMT-Ca-modified CPE (300s) [64] and 50 nM for the second one [65].…”
Section: Voltammetric Methodsmentioning
confidence: 82%
“…Voltammetry is another rapid and sensitive analytical technique often applied for the quantification of bulk drug or pharmaceutical formulations in various matrices [61][62][63]. There are two developed voltammetric methods for DIF determination alone [64] or with Piroxicam at DIF-derived gold nanoparticles [65]. It is possible to quantify DIF by using a montmorillonite-Ca-modified carbon paste electrode (MMT-Ca-modified CPE) [64] or differential pulse voltammetry with a modified glassy carbon electrode (DPV GCE) [65].…”
Section: Voltammetric Methodsmentioning
confidence: 99%
See 1 more Smart Citation