2015
DOI: 10.1016/j.bios.2014.08.043
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive electrochemical immunosensor for carbohydrate antigen 72-4 based on dual signal amplification strategy of nanoporous gold and polyaniline–Au asymmetric multicomponent nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
36
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 82 publications
(37 citation statements)
references
References 41 publications
1
36
0
Order By: Relevance
“…As signal amplification and noise reduction are crucial for achieving low detection limits in clinical immunoassays, researchers have been devoted to proposing new kinds of detection methods or materials to achieve the above goals. Owing to the unique characteristics of nanoparticles, many of them have been used in the signal amplification strategy, such as quantum dots (Zhao et al, 2012;Wen et al, 2013) and metal nanoparticles (Fan et al, 2014;Li et al, 2012). In addition, enzyme labeling (Sheng and Zheng, 2009;Yan et al, 2012) is the most commonly employed labeling method not only for the intrinsic catalytic activity of enzyme but also for its high efficiency and specificity.…”
Section: Introductionmentioning
confidence: 99%
“…As signal amplification and noise reduction are crucial for achieving low detection limits in clinical immunoassays, researchers have been devoted to proposing new kinds of detection methods or materials to achieve the above goals. Owing to the unique characteristics of nanoparticles, many of them have been used in the signal amplification strategy, such as quantum dots (Zhao et al, 2012;Wen et al, 2013) and metal nanoparticles (Fan et al, 2014;Li et al, 2012). In addition, enzyme labeling (Sheng and Zheng, 2009;Yan et al, 2012) is the most commonly employed labeling method not only for the intrinsic catalytic activity of enzyme but also for its high efficiency and specificity.…”
Section: Introductionmentioning
confidence: 99%
“…Calibration curves were obtained in the range 10 3 –5.10 5 cells mL −1 , with a LoD of 400 cells mL −1 . Direct detection of carbohydrate antigens (CA72-4) was also reported by Fan et al [124] using nanoporous gold as substrate and polyaniline-AuNPs (PANi-AuPt) as label. The signaling antibody (Ab 2 ) was adsorbed onto the PANi-AuNPs and served as catalyst for H 2 O 2 oxidation (added in solution).…”
Section: Discussionmentioning
confidence: 63%
“…The drawback here is the possibility of redox species leakage, which would affect the stability of the label-free electrochemical immunosensor. Although previous studies have introduced enzyme catalysis to achieve a higher electrochemical signal, this could increase the complication and expenses of the immunosensor preparation 3436 . Considering the above situations, it is of great significance to develop a new type of multifunctional substrate that can provide a redox signal, amplify the signal, and immobilise antibodies for use in a label-free electrochemical immunosensor.…”
Section: Introductionmentioning
confidence: 99%