2013
DOI: 10.1563/aaid-joi-d-11-00126
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasonic Oscillations for Conservative Retrieval of a Rare Fracture of Implant Healing Abutment

Abstract: Dental implants can be rendered useless because of complications related to implant components such as the fracture of abutment screw and prosthetic retaining screw. Removal of such fractured fragments is therefore deemed necessary for the sake of prosthetic restoration. This case report presents a rare incident of healing abutment fracture and details the stepwise and probably the most conservative clinical technique using ultrasonic oscillations for retrieval of fractured screw fragment without affecting the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 11 publications
0
10
0
1
Order By: Relevance
“…This can be achieved by following some specific principles such as placing an adequate number of implants with respect to the extent of the edentulous area, applying appropriate tightening torque as recommended by the manufacturer, applying a pretorque to ensure that implant components are fitted precisely, and removing the loosened screws instead of retightening them. In fact, regular follow‐ups play a key role to prevent screw loosening and fracture of implants …”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…This can be achieved by following some specific principles such as placing an adequate number of implants with respect to the extent of the edentulous area, applying appropriate tightening torque as recommended by the manufacturer, applying a pretorque to ensure that implant components are fitted precisely, and removing the loosened screws instead of retightening them. In fact, regular follow‐ups play a key role to prevent screw loosening and fracture of implants …”
Section: Discussionmentioning
confidence: 99%
“…In fact, regular follow-ups play a key role to prevent screw loosening and fracture of implants. 12 However, when abutment fracture occurs, the remaining part must be removed gently in order not to damage the internal threads of the implant. This could be extremely difficult for the clinicians since no specific method has been introduced for this purpose.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Kırık vidanın implant iç yüzeyine zarar verilmeden çıkartılması klinik açıdan büyük zorluk arz etmektedir. 16 Bu nedenle literatürde pek çok farklı yöntem belirtilmiştir 4,13-14 ve implant üreticilerine ait pek çok vida çıkarma seti kullanılabilmektedir. 17 Bu yöntem ve setlerin kullanımı zaman tüketimi açısından uygun değildir, bununla birlikte bu işlemler implant iç yüzeyine zarar verebilmektedir.…”
Section: Discussionunclassified