Unblocking function of distance relay during power swing based on modal analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0
2

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 14 publications
0
2
0
2
Order By: Relevance
“…This method is not dependent on the network topology and, unlike the conventional blinder technique, does not require lots of stability studies to find the relay settings. An algorithm based on participatory factors acquired from the variance/covariance matrix is ​proposed in [88]. In this method, modal analysis is applied to obtain more properties for the transient response to the matrix, and a threshold for the difference between fault and PS is identified.…”
Section: Detection Of Power Swingmentioning
confidence: 99%
“…This method is not dependent on the network topology and, unlike the conventional blinder technique, does not require lots of stability studies to find the relay settings. An algorithm based on participatory factors acquired from the variance/covariance matrix is ​proposed in [88]. In this method, modal analysis is applied to obtain more properties for the transient response to the matrix, and a threshold for the difference between fault and PS is identified.…”
Section: Detection Of Power Swingmentioning
confidence: 99%
“…A probabilidade de ocorrência de OP envolvendo várias máquinas aumenta. Nesse caso, o centro elétrico do sistema pode se mover dinamicamente por diferentes rotas, invalidando o modelo tradicional de análise de fonte dupla (TORRES et al, 2017). Existem diversos trabalhos que analisam a performance dos métodos tradicionais de bloqueio por oscilação de potência em sistema de dois terminais.…”
Section: Introductionunclassified
“…No SEP interconectado, a probabilidade de ocorrência de OP envolvendo várias máquinas aumenta. Nesse caso, o centro elétrico do sistema pode se mover dinamicamente por diferentes rotas, invalidando o modelo tradicional de análise de fonte dupla (Torres et al, 2017). Existem diversos trabalhos que analisam a performance dos métodos tradicionais de bloqueio por oscilação de potência em sistema de várias máquinas.…”
Section: Introductionunclassified