Uncertainty analysis for trace-moisture standard realized using a magnetic suspension balance/diffusion-tube humidity generator developed at NMIJ

Abstract: A method of estimating the uncertainty for a primary trace-moisture standard realized using a magnetic suspension balance/diffusion-tube humidity generator (MSB/DTG) developed at the National Metrology Institute of Japan (NMIJ) is reported in full detail. The results of uncertainty analysis showed that the relative expanded uncertainties of the trace-moisture standard with a coverage factor of k = 2 are 6.9 % to 0.75 % for the amountof-substance fractions (mole fractions) of water in nitrogen in the range of 1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(16 citation statements)
references
References 15 publications
0
16
0
Order By: Relevance
“…NMIJ developed three trace-moisture generators using the diffusion method [7,[27][28][29][30][31][32][33]. In this section, the magnetic-suspensionbalance/diffusion-humity genertor (MSB/DTG), which was the first generator developed at NMIJ is briefly presented.…”
Section: Development Of Trace-moisture Standardsmentioning
confidence: 99%
See 1 more Smart Citation
“…NMIJ developed three trace-moisture generators using the diffusion method [7,[27][28][29][30][31][32][33]. In this section, the magnetic-suspensionbalance/diffusion-humity genertor (MSB/DTG), which was the first generator developed at NMIJ is briefly presented.…”
Section: Development Of Trace-moisture Standardsmentioning
confidence: 99%
“…The standard uncertainty [35] of the trace-moisture standard realized using the MSB/DTG at the NMIJ evaluated, as summarized in Table 1 [31]. An international comparison of primary trace-moisture standards established by NMIs was organized by the European Association of National Metrology Institutes (EURAMET), and NMIJ participated in this comparison [8].…”
Section: Uncertainty Evaluation and International Comparisonmentioning
confidence: 99%
“…This was because the derivative of the discharge coefficient with respect to P u at 84 kPa for Q 3 is six times greater than that at 612 kPa for Q 2 ; therefore, Q 3 was more susceptible to fluctuations in P u than Q 2 . This can also be explained using equations ( 5)- (10): equation (5) shows that Q m is proportional to C d . Equation (7) indicates that C d becomes more susceptible to change in Re Th as Re Th decreases.…”
Section: Control and Measurement Of δQmentioning
confidence: 99%
“…Performance testing or calibration based on experiments traceable to the International System of Units (SI) is essential for reliable measurement, but is impossible to practice without primary standards. The National Metrology Institute of Japan (NMIJ) established a primary trace-moisture standard in N 2 [3][4][5]. NMIJ tested the performance of some commercial measuring instruments on the basis of the trace-moisture standard and found that those measuring instruments do not have a sufficient measurement capability in the range below 100 nmol mol −1 [4], despite manufacturers' performance claims.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation