2010
DOI: 10.1063/1.3475385
|View full text |Cite
|
Sign up to set email alerts
|

Uncertainty analysis technique for OMEGA Dante measurements

Abstract: The Dante is an 18 channel X-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g. hohlraums, etc.) at X-ray energies between 50 eV to 10 keV. It is a main diagnostics installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the X-ray diodes, filters and mirrors and an unfold algorithm. Understanding the errors on this absolute measu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 39 publications
(7 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…3 are the experimental and simulated x-ray power profiles for the (a) 0-8 keV and (b) 8-20 keV emission for Dante-1 (red) and Dante-2 (blue); since the spectral resolution of the Dante is poor, we show only broad-band fluxes. The shaded areas indicate a fixed 615% uncertainty about the experimental value 26 and simulated profiles are shown as solid lines. In good agreement with the Dante data, 13 the spatially integrated simulated 0-20 keV XRCE is տ53% and the Kr K-shell (8-20 keV) XRCE is 3.5%.…”
Section: B Benchmarking With Kr Datamentioning
confidence: 99%
“…3 are the experimental and simulated x-ray power profiles for the (a) 0-8 keV and (b) 8-20 keV emission for Dante-1 (red) and Dante-2 (blue); since the spectral resolution of the Dante is poor, we show only broad-band fluxes. The shaded areas indicate a fixed 615% uncertainty about the experimental value 26 and simulated profiles are shown as solid lines. In good agreement with the Dante data, 13 the spatially integrated simulated 0-20 keV XRCE is տ53% and the Kr K-shell (8-20 keV) XRCE is 3.5%.…”
Section: B Benchmarking With Kr Datamentioning
confidence: 99%
“…A second consistency check was done using the diagnostic DANTE [50][51][52] . This instrument is an absolutely calibrated diode-array spectrometer.…”
Section: A Validation Of Target Orientationmentioning
confidence: 99%
“…Ref. [ 13 , 24 , 25 ], the DMX in France [ 26 ], and the soft X-ray spectrometer used on Shenguang laser facilities in Mianyang, China [ 27 ].…”
Section: Soft X-ray Spectrometer and Compressive Sensingmentioning
confidence: 99%
“…One technique is selecting the reasonable basis function to reconstruct the spectrum. The response function [ 10 ], Piece-wise B-spline [ 10 , 11 ], and Gaussian Bumps, among others [ 12 , 13 , 14 ], are shapes of the basis function frequently used in spectrum unfolding experiments. By using these basis functions, basis atoms should be selected in some certain rules in advance.…”
Section: Introductionmentioning
confidence: 99%