Univer Project. A grid connected photovoltaic system of 200kWp at Jaén University. Overview and performance analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 108 publications
(29 citation statements)
references
References 1 publication
0
29
0
Order By: Relevance
“…Almonacid et al (2011) does an analysis in this respect that deserves a closer look. (Drif et al 2007) consisting of the installation of a grid-connected PV system with a total power of 200 kWp, in Jaen University Campus. The relative errors of the above models applied to these systems are summarized in Fig.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Almonacid et al (2011) does an analysis in this respect that deserves a closer look. (Drif et al 2007) consisting of the installation of a grid-connected PV system with a total power of 200 kWp, in Jaen University Campus. The relative errors of the above models applied to these systems are summarized in Fig.…”
Section: Discussionmentioning
confidence: 99%
“…10.8 Bi-monthly forecasting errors and 6 months forecasting errors of the electrical energy from PV plant for 1 day horizon. Data from have been used to build the graph against field data, collected on a 2.2 kW p PV system consisting of 20 Isofoton I-106 crystalline modules, part of the UNIVER project at Jaen University in Spain (Drif et al 2007). In this experiment the PV generator was configured in four strings of five series-connected modules with a facility to rapidly change the module interconnection scheme.…”
Section: Comparison Of Models Performancementioning
confidence: 99%
“…Based on related study and monitoring of practical projects, the general efficiency of the above two systems is around 65%-85% (Drif, Pérez et al, 2007;Rehman and El-Amin, 2012) (3) Management Schemas and ambient conditions Even it is less important, The management manner of PV system such as depth of battery discharge, automatic adjustment of PV panel tilt angle and orientation, and ambient conditions of the PV module such as temperature, dust and dirt on the panel, air humidity etc., will influence the performance of solar panel not to be working at the peak watt.…”
Section: Solar Power Potential Calculation Of the Study Citiesmentioning
confidence: 99%
“…This is the most frequently used NOTC model to determine the value of T c [4, 29,37,47,[53][54][55][56][57][58][59], but, in this case, the parameter T INOCT is used instead of the normally used T NOCT . This latter value is Energies 2017, 10,1964 4 of 26 defined as the Normal Operating Cell Temperature (NOCT) and represents the mean PV cell junction temperature in the so-called Nominal Terrestrial Environment (NTE) conditions (ambient temperature T a,NTE = 20 • C, wind speed v NTE = 1 m/s on the front and back sides of the PV module and irradiance G NTE = 800 W/m 2 ) in an open-rack mounted, open-circuit module tilted perpendicular to the solar noon.…”
Section: Introductionmentioning
confidence: 99%