Unsupervised detection and classification of heartbeats using the dissimilarity matrix in PCG signals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…Next, we further refine the signal by implementing a band-pass filter. This filter restricts the frequency range of the spectrogram to a band spanning 300 to 2000 Hz, a spectral interval where most of the respiratory content can be found [36,37], given that cardiac and other body sounds lay under 300 Hz and, yet, most of the lung noises can be foundabove this threshold.…”
Section: Signal Preprocessingmentioning
confidence: 99%
“…Next, we further refine the signal by implementing a band-pass filter. This filter restricts the frequency range of the spectrogram to a band spanning 300 to 2000 Hz, a spectral interval where most of the respiratory content can be found [36,37], given that cardiac and other body sounds lay under 300 Hz and, yet, most of the lung noises can be foundabove this threshold.…”
Section: Signal Preprocessingmentioning
confidence: 99%
“…Because stethoscopes are sensitive to environmental noises and other sounds from the human body (e.g., respiratory sounds, lung sounds, rumbling of the stomach and intestine), denoising is strongly required to improve the accuracy of heart sounds localization [ 10 , 17 , 18 , 19 , 20 , 21 ]. Several techniques, such as short-time Fourier transform, fast Wavelet transform, tunable-Q Wavelet transform, and S transform, have been used to accomplish this task [ 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 ]. Different approaches have been proposed in the literature for heart sounds localization.…”
Section: Introductionmentioning
confidence: 99%
“…However, the sole thresholding operation often fails to selectively detect peaks related to heart sounds. Nevertheless, the great part of the envelogram-based methods is unable to discriminate S1 and S2 [ 23 , 26 , 29 , 32 ], or they need to consider additional criteria such as the typical duration of systole and diastole, to distinguish them [ 22 , 24 , 28 , 31 , 33 , 34 ].…”
Section: Introductionmentioning
confidence: 99%
“…Given the convenience and feasibility of using a stethoscope to acquire heart rate data, PCG signals have been employed as raw data input to the classification model in the proposed work for detecting heart health status. In the literature, both supervised (Das et al, 2019; Moulana et al, 2022) and unsupervised (Das et al, 2020; Torre‐Cruz et al, 2022) approaches of heart health status detection have been reported. The unsupervised methods, despite their potential, have some limitations about their usability and accuracy (Safara et al, 2012).…”
Section: Introductionmentioning