2014
DOI: 10.1016/j.mvr.2014.06.007
|View full text |Cite
|
Sign up to set email alerts
|

Update on retinal vessel structure measurement with spectral-domain optical coherence tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
25
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(28 citation statements)
references
References 27 publications
2
25
1
Order By: Relevance
“…Previous studies involving direct measurements of vessel diameters using the Image J software (National Institutes of Health, Bethesda, MD, USA) reported high repeatability and reproducibility. 11,14 In our study, the intra-and interobserver ICCs for OCT vessel diameter measurements were also highly repeatable and reproducible, especially in measuring the luminal diameter, the ICCs were 40.90. Other parameter measurements also had relatively good ICCs of 40.80.…”
Section: Discussionsupporting
confidence: 62%
See 2 more Smart Citations
“…Previous studies involving direct measurements of vessel diameters using the Image J software (National Institutes of Health, Bethesda, MD, USA) reported high repeatability and reproducibility. 11,14 In our study, the intra-and interobserver ICCs for OCT vessel diameter measurements were also highly repeatable and reproducible, especially in measuring the luminal diameter, the ICCs were 40.90. Other parameter measurements also had relatively good ICCs of 40.80.…”
Section: Discussionsupporting
confidence: 62%
“…Different sizes of the inner and outer walls were also reported in previous studies. 11,14 The inner walls were thicker compared with the outer walls, with 75% in arteries (30/40, data not shown) and 82.5% in veins (33/40, data not shown). In general, the inner wall was more intense and thicker compared with the outer wall because of decreases in light intensity at increasing distances.…”
Section: Discussionmentioning
confidence: 90%
See 1 more Smart Citation
“…There is a single report of a decrease in relative blood flow to the optic nerve head in MS eyes, measured using OCT angiography [25]. However, this technique is not yet widely available in the clinical setting, compared to quantitative static retinal blood vessel metrics which can be extracted from OCT scans that are acquired using currently available clinical instrumentation [26][27][28]. We sought to investigate quantitative retinal blood vessel metrics as a marker of MS using a cross sectional study of retinal blood vessel diameters in individuals with and without MS, and with and without a history of ON.…”
Section: Introductionmentioning
confidence: 99%
“…However, we should note that the concept of ERI does not mean a complete restoration of high-resolution images without additional image information but image enhancement. We believe that the ERI method is useful as a type of display format in the analysis of fine structures in OCT images such as hyper-reflective foci [31,32,33,37], the retinal nerve fiber layer near the fovea [38,39], intricately affected photoreceptor layers [40,41], and vessels [42,43]. Further, MBP as well as IBP suffer from the drawback of noise enhancement.…”
Section: Discussionmentioning
confidence: 99%