Upgraded bolometer system on JET for improved radiation measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
72
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 91 publications
(73 citation statements)
references
References 9 publications
1
72
0
Order By: Relevance
“…It is interesting to note that although the C 6+ content is similar in the two cases, the C 4+ concentration exhibits a much stronger increase with ICRF power in the N = 2 3 He heating case, suggesting that most of the radiation losses in these discharges come from the outer region of the plasma rather than from the plasma core. 2D bolometric tomography [29] confirmed this hypothesis and revealed that a significant part of the radiation observed in the 3 He heating discharges comes from the plasma periphery and from the divertor region.…”
Section: Impurity Generation and Performance Comparisonmentioning
confidence: 65%
“…It is interesting to note that although the C 6+ content is similar in the two cases, the C 4+ concentration exhibits a much stronger increase with ICRF power in the N = 2 3 He heating case, suggesting that most of the radiation losses in these discharges come from the outer region of the plasma rather than from the plasma core. 2D bolometric tomography [29] confirmed this hypothesis and revealed that a significant part of the radiation observed in the 3 He heating discharges comes from the plasma periphery and from the divertor region.…”
Section: Impurity Generation and Performance Comparisonmentioning
confidence: 65%
“…The D 2 gas fuelling into the inner divertor scrape-off layer has been progressively decreased from a fuelling rate of C gas = 10 22 molecules/s to C gas = 0 to produce a scan in ELM amplitude and frequency at high W plasma ($8 MJ). The JET bolometer camera system has recently been substantially upgraded, allowing significantly improved spatial and temporal resolution of the radiation distribution (Dr $ 8 cm in the divertor region, Dt $ 1 ms), particularly in the divertor region [2]. This allows a greatly improved tomographic reconstruction of the radiation pattern on a timescale of the order of the typical duration of a Type I ELM cycle ($1 ms).…”
Section: Experimental Set-upmentioning
confidence: 99%
“…The tool was once developed for the measurement and assessment of the ITER bolometer diagnostic [7] and is based on work conducted at JET [12] [13]. Experience to analyse and evaluate the results were gained during the collimator development for ITER [14].…”
Section: Experimental Set-upmentioning
confidence: 99%