The main stages of a calculation and experimental analysis of measures aimed at achieving better power performance of a nuclear power station and a procedure for carrying out such analysis are considered. The results of a calculated and experimental assessment of the power performance effect from modernization of the moisture separators steam superheaters used in turbine generators Nos. 7 and 8 of Unit 4 at the Len ingrad nuclear power station are presented.