Use of a low-resistance compliant thoracic artificial lung in the pulmonary artery to pulmonary artery configuration

Abstract: Background Thoracic artificial lungs (TALs) have been proposed as a bridge to transplant in patients with end-stage lung disease. Systemic embolic complications can occur following TAL attachment in the pulmonary artery to left atrium (PA-LA) configuration. Therefore, we evaluated the function of a compliant TAL (cTAL) attached via the proximal PA to distal main PA configuration. Methods The cTAL was attached to five (63 ± 0.9 kg) sheep in the PA-PA configuration. Device function and animal hemodynamics were… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…1719 However, the baseline resistance in this study was 1 mmHg/(L/min). In previous studies, the device was positioned ideally, sitting flat on the animal.…”
Section: Discussionmentioning
confidence: 61%
See 2 more Smart Citations
“…1719 However, the baseline resistance in this study was 1 mmHg/(L/min). In previous studies, the device was positioned ideally, sitting flat on the animal.…”
Section: Discussionmentioning
confidence: 61%
“…18,19 Overall, the cTAL demonstrated its capability to be used for at least two weeks without anti-coagulant coatings, and likely longer with more sophisticated biomaterials approaches. The device maintained a low, constant resistance.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…43 Compliant ALs and circuits have been developed to achieve impedances even lower than the natural lung. [44][45][46] Circuit compliance will be an important consideration for the development and implementation of the Pediatric MLung; however, in this work, we have focused solely on the resistance aspect of the AL. Future work will done to incorporate the proper level of compliance to the circuit.…”
Section: Discussionmentioning
confidence: 99%
“…39 Compliant artificial lungs and circuits have been developed to achieve impedances even lower than the natural lung. 4042 Circuit compliance will be an important consideration for the development and implementation of the Pediatric MLung, however in this work we have focused solely on the resistance aspect of the artificial lung. Future work will done to incorporate the proper level of compliance to the circuit.…”
Section: Discussionmentioning