2003
DOI: 10.1366/00037020360625970
|View full text |Cite
|
Sign up to set email alerts
|

Use of a Sample Translation Technique to Minimize Adverse Effects of Laser Irradiation in Surface-Enhanced Raman Spectrometry

Abstract: Surface-enhanced Raman spectroscopy (SERS) has proven to be a very powerful tool in the analysis of a wide range of compounds. However, continuous irradiation of the laser beam over the SERS substrate can promote the gross decomposition of the sample analytes and significantly broaden and diminish the intensities of observed spectral bands. In addition, the incident radiation can promote thermal or photolytic fragmentation of analytes, thereby altering the observable bands and possibly leading to a misinterpre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
80
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 42 publications
(80 citation statements)
references
References 33 publications
0
80
0
Order By: Relevance
“…Experimentally, this is revealed by following the decreasing ratio of a prominent, descriptive resorufin band at 573 cm 21 to the graphitic carbonaceous band, a harbinger of polymer and resorufin degradation, at 740-950 cm 21 (Fig. 3a).…”
Section: Factors Influencing Sensitivity and Dynamic Rangementioning
confidence: 98%
See 1 more Smart Citation
“…Experimentally, this is revealed by following the decreasing ratio of a prominent, descriptive resorufin band at 573 cm 21 to the graphitic carbonaceous band, a harbinger of polymer and resorufin degradation, at 740-950 cm 21 (Fig. 3a).…”
Section: Factors Influencing Sensitivity and Dynamic Rangementioning
confidence: 98%
“…The stage was then reprogrammed to take smaller steps with averaging of three latitudinal spatially distinct spectra within the same longitudinal location along the channel's length. This step recreates the electrophoretic band shape by following the intensity of resorufin's vibrational band at 573 cm 21 . Raman data was processed with LabSpec software, Version 4.03.…”
Section: Separation and Detection Apparatusmentioning
confidence: 99%
“…This ensures that neither of the two adjacent MCs have been coated with the phase that has been applied to the MC shown. This coating approach has been applied to the measurement of a mixture of quinoxaline and 8-hydroxyquinoline in solution by coating two adjacent MCs with calix [6]arene and calix [8]arene, respectively.…”
Section: Methods Of Differentially Applying Novel Macrocycle Receptormentioning
confidence: 99%
“…We discovered that the photodegredation problem can be overcome by very effectively rastering the laser spot onto new areas of the SERS substrate to prevent photodegredation without loss of signal. 8 The long desorption times of adsorbed molecules is a more complex problem that may require the development of thermal desorption methods.…”
Section: Exploring Microcantilever Compatible Surface Enhanced Raman mentioning
confidence: 99%
“…This coating approach has been applied to the measurement of a mixture of quinoxaline and 8-hydroxyquinoline in solution by coating two adjacent MCs with calix [6]arene and calix [8]arene, respectively. Calibration curves were obtained for each analyte independently using each phase and response factors were calculated using this data.…”
mentioning
confidence: 99%