2009
DOI: 10.1007/s00464-009-0554-8
|View full text |Cite
|
Sign up to set email alerts
|

Usefulness in NOTES of an intra-abdominal antifogging wireless charge-coupled device (CCD) camera with pantograph-type needle unit for placement to the intra-abdominal wall

Abstract: The wireless CCD camera unit was verified to function as an effective second eye in NOTES by using the described mechanisms and antifogging coating.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 6 publications
0
13
0
Order By: Relevance
“…We believe that the proposed system can be applied to other endoscopic surgeries, such as hybrid NOTES, SILS, and video-assisted thoracic surgery. Ohdaira et al have already proposed the use of wireless cameras for NOTES (21).…”
Section: Discussionmentioning
confidence: 99%
“…We believe that the proposed system can be applied to other endoscopic surgeries, such as hybrid NOTES, SILS, and video-assisted thoracic surgery. Ohdaira et al have already proposed the use of wireless cameras for NOTES (21).…”
Section: Discussionmentioning
confidence: 99%
“…The incorporation of irrigating channels is said to assist as is the newly developed vibration mechanism that physically cleans the lens surface. 31 Of these technical changes to laparoscopes, only the Japanese group 31,32 has studied them in detail. Laparoscopes with self-cleaning mechanisms appear not to become commercialized due to cost and practicality where additional size and potential for problems with operation or sterilization are a disadvantage.…”
Section: Principles To Assist Clear Vision During Laparoscopymentioning
confidence: 99%
“…39 Vision will be paramount with singleaccess port-type surgery in which removing instruments in and out is particularly burdensome. 31,40 Three-dimensional imaging is already in use in robot-assisted laparoscopic surgery, 41 but further advances such as optical sensors to let operator know the distance from anatomical structures are needed. 42 …”
Section: The Etiology Of Other Causes Of Poor Vision During Laparoscopymentioning
confidence: 99%
“…Therefore, from the viewpoint of invasiveness, this approach is not used. On the other hand, Ohdaira et al [8] have proposed the use of a wireless camera system for minimally invasive surgery, especially natural orifice translumenal endoscopic surgery (NOTES) [9]- [11]. The miniature camera is inserted into the patient's body via a trocar, and it transmits images of a wide operative field using a radio frequency signal.…”
Section: Introductionmentioning
confidence: 99%
“…A couple of studies have attempted to address this issue [5]- [8]. Since the early days of minimally invasive surgery, the double-endoscope method has been proposed in clinical This work is supported by the 21st century COE program, "The High Speed Hyper Human Technology Opens a New World," and a Grant-in-Aid from the Japan Society for the Promotion of Science Fellows.…”
Section: Introductionmentioning
confidence: 99%