User experience for manual injection of 2 mL viscous solutions is enhanced by a new prefillable syringe with a staked 8 mm ultra-thin wall needle

Abstract: Glezer (2020) User experience for manual injection of 2 mL viscous solutions is enhanced by a new prefillable syringe with a staked 8 mm ultra-thin wall needle,

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 46 publications
0
3
0
Order By: Relevance
“…Additionally, an innovative needle design will improve the flow rate tremendously. Shorter needles with ultra-thin wall design not only increase the net outflow, but also prevent intramuscular injection risk and injection-related anxiety [43,44]. In addition to designing a high-flow micropump, we would like to further evaluate the pumpmedium interaction.…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, an innovative needle design will improve the flow rate tremendously. Shorter needles with ultra-thin wall design not only increase the net outflow, but also prevent intramuscular injection risk and injection-related anxiety [43,44]. In addition to designing a high-flow micropump, we would like to further evaluate the pumpmedium interaction.…”
Section: Discussionmentioning
confidence: 99%
“…However, electrospraying and microglassification may necessitate long development times and the use of non-aqueous solvents for administration. 40 Additionally, there are device strategies designed to facilitate the injection of higher-viscosity solutions, such as tapered needles, 52 needles with extremely thin walls to allow for a larger interior needle diameter without increasing the exterior diameter, 53 and devices with higher-pressure injectors. 5 …”
Section: Subcutaneous Formulation Considerationsmentioning
confidence: 99%
“…45 The options to select delivery devices for viscous parenteral solutions beyond that level are numerous and multifaceted. 54 The existing arsenal ranges from using tapered needles, i.e., they have a larger diameter at their proximal end than at their distal end, to needles with ultra-thin walls while maintaining the same outer diameter, 55,56 to high pressure injectors with various pressure profiles, which are available in various types. Some are designed to inject solutions with viscosity values up to 1000 cP through 25 G needles such as the Bespak and Arc-Bios systems.…”
Section: What If Formulation Approaches Fail To Provide a "Solution"?mentioning