2019
DOI: 10.3390/ma12233934
|View full text |Cite
|
Sign up to set email alerts
|

Using 445 nm and 970 nm Lasers on Dental Implants—An In Vitro Study on Change in Temperature and Surface Alterations

Abstract: The aim of this study was to evaluate the safety of using a 445 nm laser on dental implants by comparing it with a laser with 970 nm wavelength. Two models, a pig mandible and glass ionomer cement, were used to evaluate the temperature increase in dental implants during laser irradiation with both wavelengths. Temperature was measured every second at four different places on the dental implants. Different power settings, effects of water cooling, distance of the laser fibre to the dental implant and continuous… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 23 publications
0
15
0
Order By: Relevance
“…Recent literature pointed out that the ineffectiveness of nonsurgical therapy of peri-implantitis is mainly attributable to the inefficient removal of biofilm from the complex implant surface 29 . To overcome this problem, various dental laser 1 , 23 systems have been proposed for this purpose, including diode lasers. However, previous in vitro studies on temperature increases around dental implants have shown great discrepancies between different diode lasers 24 .…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Recent literature pointed out that the ineffectiveness of nonsurgical therapy of peri-implantitis is mainly attributable to the inefficient removal of biofilm from the complex implant surface 29 . To overcome this problem, various dental laser 1 , 23 systems have been proposed for this purpose, including diode lasers. However, previous in vitro studies on temperature increases around dental implants have shown great discrepancies between different diode lasers 24 .…”
Section: Discussionmentioning
confidence: 99%
“…Eriksson and coworkers found that increasing the temperature of bone tissue by ∆T 10 °C for 60 s causes permanent changes in the bone structure 26 . Accordingly, a tissue temperature gradient ΔT below 10 °C is stated as safe when limited to 60 s 1 , 15 , 17 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations