2001
DOI: 10.1063/1.1374925
|View full text |Cite
|
Sign up to set email alerts
|

Using a 4.7 kJ Plasma Focus for introspective imaging of metallic objects and for neutronic detection of water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2006
2006
2014
2014

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 18 publications
(16 citation statements)
references
References 6 publications
0
16
0
Order By: Relevance
“…High sensitivity orthochromatic Agfa x-ray film along with a terbium-doped gadolinium oxisulfide ͑Gd 2 O 2 S:Tb͒ intensifying screen, which is one of the most widely used film-screen sets for general purpose radiography as well as for hard x-ray imaging, [11][12][13][14] was used as a hard x-ray detector.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…High sensitivity orthochromatic Agfa x-ray film along with a terbium-doped gadolinium oxisulfide ͑Gd 2 O 2 S:Tb͒ intensifying screen, which is one of the most widely used film-screen sets for general purpose radiography as well as for hard x-ray imaging, [11][12][13][14] was used as a hard x-ray detector.…”
Section: Methodsmentioning
confidence: 99%
“…11 Figures 1 and 2, respectively, show digitized images of a metallic BNC tee connector, and a 10-mm-thick aluminum block with two 1/4-20 bolts, made of steel ͑left͒ and brass ͑right͒, screwed on it. Both radiographies were taken with a single plasma focus shot, through a 9-mm-thick iron flange.…”
Section: Introductionmentioning
confidence: 99%
“…The neutrons pulses emitted by plasma focus can be used to determine the presence and after the proper calibration estimate the concentration of hydrogenated substances in the proximities of the device [7,31]. The basic idea of the method is depicted in figure 5.…”
Section: Prospection By Fast Neutrons Scatteringmentioning
confidence: 99%
“…19,20 In order to fully take advantage of the mentioned potentials, a PF device should be designed properly, providing flexibility, easy operation and maintenance, and portability. In this article, a compact design 2.5 kJ, 30 kV PF specially designed to perform as a hard x-ray radiation source suitable for flash radiography of metallic pieces is presented.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, hard x rays generated by a compact 4.7 kJ, 30 kV PF operated in deuterium were used to obtain radiographic images of metallic objects either static [18][19][20] or in fast rotation 21 and its neutron emission was used for side on water detection. 19,20 In order to fully take advantage of the mentioned potentials, a PF device should be designed properly, providing flexibility, easy operation and maintenance, and portability.…”
Section: Introductionmentioning
confidence: 99%