2005
DOI: 10.1007/s00254-005-0084-1
|View full text |Cite
|
Sign up to set email alerts
|

Using resistivity measurements for dam safety evaluation at Enemossen tailings dam in southern Sweden

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 65 publications
(30 citation statements)
references
References 8 publications
0
28
0
2
Order By: Relevance
“…The tailings produced on the PSV, which are chemically active, organic, non-geological and concentered with water contaminants, e.g., heavy metal sedimentations, should be transported to a harbor to eliminate the enormous environmental effects in the sea. This kind of tailings should undergo storage; dehydration by evaporation; consolidation by gravity, and the reinforcement materials, e.g., cement to form the tailings paste through tailings dam disposal [39].…”
Section: Tailings Disposal Methods Suitable For the Dsm Systemsmentioning
confidence: 99%
“…The tailings produced on the PSV, which are chemically active, organic, non-geological and concentered with water contaminants, e.g., heavy metal sedimentations, should be transported to a harbor to eliminate the enormous environmental effects in the sea. This kind of tailings should undergo storage; dehydration by evaporation; consolidation by gravity, and the reinforcement materials, e.g., cement to form the tailings paste through tailings dam disposal [39].…”
Section: Tailings Disposal Methods Suitable For the Dsm Systemsmentioning
confidence: 99%
“…Bu 2-B özdirenç verilerini değerlendirme yazılımında, ölçülen saha verileri ile model verileri arasındaki farkları en küçüklemek için, hem düzgünlük-kısıtlı en küçük kareler ters çözümü hem de robust ters çözüm yöntemleri kullanılmaktadır [13]. Robust ters çözüm yöntemi, yeraltı materyallerindeki elektrik iletkenlikler arasında büyük farklar olduğunda, yeraltı modelindeki keskin sınırları ortaya çıkarmada daha yeteneklidir [5]. Bu sebepten dolayı, bu çalışmadaki tüm ERI verilerinin ters çözümünde bu yöntem kullanılmıştır.…”
Section: Materyal Ve Yöntemunclassified
“…Images of subsurface bulk electrical resistivity can therefore be used to help assess geologic units that may be more likely to conduct seepage through foundation or embankment materials, or to map regions of increased saturation. Numerous resistivity studies have focused on both internal erosion detection (Cho and Yeom, 2007;Kim et al, 2007;Sjö dahl et al, 2005Sjö dahl et al, , 2008 as well as identification of seepage pathways associated with dam foundation materials (Abu-Zeid, 1994;Di and Wang, 2010;Panthulu et al, 2001).…”
Section: Self-potentialmentioning
confidence: 99%
“…These tasks are accomplished through the use of two complementary electrical geophysical methods, self-potentials (SP) and direct-current (DC) electrical resistivity, which have been commonly used in dam seepage and other integrated hydrogeologic studies (Berube, 2007;Ogilvy, 1970a, 1970b;Bolève et al, 2009;Corwin, 2007;Dahlin et al, 2008;Ogilvy et al, 1969;Panthulu et al, 2001;Sheffer, 2007;Sjö dahl et al, 2005Sjö dahl et al, , 2008Titov et al, 2005). SP is a passive method that is primarily sensitive to active subsurface groundwater flow and seepage, whereas DC resistivity is an activesource method that can provide information about changes in subsurface lithology and groundwater saturation.…”
Section: Introductionmentioning
confidence: 99%