2008
DOI: 10.1016/j.bpobgyn.2008.08.009
|View full text |Cite
|
Sign up to set email alerts
|

Uterine artery embolization for postpartum hemorrhage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
5

Year Published

2011
2011
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 84 publications
(15 citation statements)
references
References 47 publications
0
10
0
5
Order By: Relevance
“…Thus, this indication is still controversial [32,[41][42][43][44][45][46][47][48]. Patients with fibroids and multiple pregnancies may be indicated for prophylactic IR, though only three cases with successful bleeding control have been reported.…”
Section: Specific Commentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, this indication is still controversial [32,[41][42][43][44][45][46][47][48]. Patients with fibroids and multiple pregnancies may be indicated for prophylactic IR, though only three cases with successful bleeding control have been reported.…”
Section: Specific Commentsmentioning
confidence: 99%
“…Hematoma at the puncture site. (Grade C1) Specific comments [22,26,32,[41][42][43][44][45][46][47][48] Complications from prophylactic insertion of occlusion balloon catheters include angiography, thromboembolic events, and damaged balloons resulting in the failure of efficient occlusion of the arteries. The safe radiation dose for the fetus has not been reported; however, the reported fluoroscopy time was less than 5 min; thus, the dose is estimated as <50 mGy.…”
Section: Cqmentioning
confidence: 99%
“…[5][6][7] Many researchers have focused on patient radiation exposure in UAE. Nikolic et al 2 reported that the absorbed ovarian dose and absorbed skin dose during UAE could be reduced by using pulsed fluoroscopy instead of nonpulsed fluoroscopy.…”
Section: Discussionmentioning
confidence: 99%
“…5 One TLD was attached to the left wrist on the palmar side and the other one was placed on the left outer side of the thyroid collar of the operator in each operation. The palmar side was chosen because the X-ray tube was located under the examination table; thus, this side was more likely to be directly exposed to the X-ray radiation.…”
Section: Radiation Exposure Measurementmentioning
confidence: 99%
“…iliaca internae platziert, die sowohl eine Drosselung der Blutzufuhr als auch eine selektive Katheterembolisation ermöglichen. Allerdings sind die klinischen Erfahrungen mit dieser speziellen Zentren vorbehaltenen Methode noch unzureichend [51].…”
Section: Selektive Katheterembolisation Der Aa Uterinaeunclassified