2016
DOI: 10.1016/j.rprh.2016.11.009
|View full text |Cite
|
Sign up to set email alerts
|

Utilidad de un método que determina simultáneamente retinol y α-tocoferol en leche materna por cromatografía líquida de alta resolución

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“… 25 Antioxidant activity limits the generation of free radicals 26 and can be measured by chemical, 27 electrochemical, 28 or cellular methods. 29 Its effectiveness is evaluated with physiologically active antioxidants such as glutathione, 30 α-tocopherol, 31 ergothioneine, 32 and synthetics such as Trolox, 33 BHT, 34 and BHA. 35 …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“… 25 Antioxidant activity limits the generation of free radicals 26 and can be measured by chemical, 27 electrochemical, 28 or cellular methods. 29 Its effectiveness is evaluated with physiologically active antioxidants such as glutathione, 30 α-tocopherol, 31 ergothioneine, 32 and synthetics such as Trolox, 33 BHT, 34 and BHA. 35 …”
Section: Introductionmentioning
confidence: 99%
“…25 Antioxidant activity limits the generation of free radicals 26 and can be measured by chemical, 27 electrochemical, 28 or cellular methods. 29 Its effectiveness is evaluated with physiologically active antioxidants such as glutathione, 30 α-tocopherol, 31 ergothioneine, 32 and synthetics such as Trolox, 33 BHT, 34 and BHA. 35 Most studies that measure antioxidant activity using silver nanoparticles are based on methods such as DPPH (2,2-diphenyl-1-picryl-hydrazyl-hydrate), ABTS (2,2ʹazino-bis [3-ethylbenzothiazoline-6-sulfonic acid]), and FRAP (ferric reducing ability of plasma), among others.…”
Section: Introductionmentioning
confidence: 99%
“…Tocopherol extraction was carried out as explained by Shiozaki & Murakami (2016) and α-tocopherol was quantified as described by Martínez-Rojano et al (2016). Two mL of ethanol was added to grape seed oil extract, passed through 0.2 µm pore nylon filters and injected into the HPLC equipment (Series 200, Perkin Elmer, USA) with a UV detector at 290 nm, equipped with a Kromasil C18 reversed phase column of 5 µm and dimensions 4.6 x 150 mm.…”
Section: α-Tocopherolmentioning
confidence: 99%
“…Tocopherol extraction was carried out as explained by Shiozaki and Murakami [18] and α-tocopherol was quantified as described by Martínez-Rojano et al [19]. Two mL of ethanol were added to the grape seed oil extract, passed through 0.2 µm pore nylon filters and injected into the HPLC equipment (Series 200, Perkin Elmer, USA) with a UV detector at 290 nm, equipped with a Kromasil C18 reversed phase column of 5 µm and dimensions of 4.6 x 150 mm.…”
Section: α-Tocopherolmentioning
confidence: 99%