2018
DOI: 10.1016/j.saa.2017.11.045
|View full text |Cite
|
Sign up to set email alerts
|

Utilization of a lateral flow colloidal gold immunoassay strip based on surface-enhanced Raman spectroscopy for ultrasensitive detection of antibiotics in milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(20 citation statements)
references
References 38 publications
0
20
0
Order By: Relevance
“…The LOD value was 1.07 ng/L in the presented IC-TRFIA for Van, which is more sensitive (approximately 60-fold) compared with Kong et al (2017) established IC-ELISA for Van with LOD value of 0.06 ng/mL, and approximately 460-fold, 2.0 × 10 5 -fold and 2.5 × 10 5 -fold compare with Liang et al (2015), Sheng and Zhou (2017) and Usman and Hempel (2016) which were established fluorescence "turn-off" biosensor, two-dimensional liquid chromatography and HPLC for Van with LOD value of 0.46 ng/mL, 0.2 and 0.25 μg/mL respectively. In addition, it was slightly better than Liu, Yan, Hua, and Wang (2013), Hu et al (2018), Zhou et al (2015) and Sheng et al (2016) established IC-TRFIAs for thiacloprid, aflatoxin B 1 , chloramphenicol and diniconazole with LOD value of 1.9, 3.55, 8.0 and 21 ng/L, respectively. At present, the Van belongs to a banned antibiotic drug in animal food in China, although there is no maximum residue limit standard of Van in it, the LOD value of 1.07 ng/L in the presented IC- Figure 3.…”
Section: Ic-trfia Establishment Of Van and Its Analoguesmentioning
confidence: 91%
See 1 more Smart Citation
“…The LOD value was 1.07 ng/L in the presented IC-TRFIA for Van, which is more sensitive (approximately 60-fold) compared with Kong et al (2017) established IC-ELISA for Van with LOD value of 0.06 ng/mL, and approximately 460-fold, 2.0 × 10 5 -fold and 2.5 × 10 5 -fold compare with Liang et al (2015), Sheng and Zhou (2017) and Usman and Hempel (2016) which were established fluorescence "turn-off" biosensor, two-dimensional liquid chromatography and HPLC for Van with LOD value of 0.46 ng/mL, 0.2 and 0.25 μg/mL respectively. In addition, it was slightly better than Liu, Yan, Hua, and Wang (2013), Hu et al (2018), Zhou et al (2015) and Sheng et al (2016) established IC-TRFIAs for thiacloprid, aflatoxin B 1 , chloramphenicol and diniconazole with LOD value of 1.9, 3.55, 8.0 and 21 ng/L, respectively. At present, the Van belongs to a banned antibiotic drug in animal food in China, although there is no maximum residue limit standard of Van in it, the LOD value of 1.07 ng/L in the presented IC- Figure 3.…”
Section: Ic-trfia Establishment Of Van and Its Analoguesmentioning
confidence: 91%
“…The cross-reactivity (CRs) of antibody to antigen analogue (contains structural and functional analogues) is an important indicator for specificity evaluation in the field of immunoassay (He et al, 2019;Luo et al, 2017;Shi et al, 2018). As showed in Table 1, the presented IC-TRFIA showed strong CRs of 36.2% for norvancomycin, and hardly binding to polymyxin B (less than 0.1%), kanamycin (not detected) and ampicillin (not detected).…”
Section: Ic-trfia Establishment Of Van and Its Analoguesmentioning
confidence: 99%
“…The Raman intensity of peak at 1078 cm −1 on the test line was determined and used for the quantitative determination of neomycin. The whole process could be completed within 15 min with a LOD of 0.216 pg mL −1 and good specificity [78]. Homogeneous SERS was developed for the detection of kanamycin in milk samples based on bimetallic Au@Ag NPs.…”
Section: Surface-enhanced Raman Spectroscopymentioning
confidence: 99%
“…e strip method mainly uses immune or competitive reactions to initiate or prevent the aggregation of colloidal gold nanoparticles on the paper strip detection line. e detection line shows red or colorless to indicate the presence or absence of the target molecules [12,13]. e computer-aided discriminant analysis is mainly based on the data information of spectroscopy, chromatography, mass spectrometry, and so on, of the samples and combined with the chemometrics algorithm [14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%