2020
DOI: 10.1016/j.saa.2020.118509
|View full text |Cite
|
Sign up to set email alerts
|

Validated spectrofluorimetric method for determination of mirabegron by utilizing its quenching effect on acetoxymercuric fluorescein reagent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 13 publications
0
11
0
Order By: Relevance
“…3) [9], this reaction decreases the intensity of the (AMF)fluorescence that measured quantitatively with the tested compounds [10][11][12]. Many compounds successfully determined quantitively using this method such as mesna, acetylcysteine, timonacic corrosive [13], penicillamine [14] and mirabegron [15]. In this study, the reaction of IXB with its sulfide group with AMF and the quenching effect on the fluorescence were measured spectrofluorimetricaly at (ƛ em 530 nm) [9].…”
Section: Ixabepilonementioning
confidence: 95%
“…3) [9], this reaction decreases the intensity of the (AMF)fluorescence that measured quantitatively with the tested compounds [10][11][12]. Many compounds successfully determined quantitively using this method such as mesna, acetylcysteine, timonacic corrosive [13], penicillamine [14] and mirabegron [15]. In this study, the reaction of IXB with its sulfide group with AMF and the quenching effect on the fluorescence were measured spectrofluorimetricaly at (ƛ em 530 nm) [9].…”
Section: Ixabepilonementioning
confidence: 95%
“…Literature review showed different methods for the determination of MIR using UV spectrophotometric [3] , spectrofluorometric [4] , chromatographic methods [5–7] LC‐MS/MS [8,9] .…”
Section: Introductionmentioning
confidence: 99%
“…The research was conducted on the Blend Uniformity (BU) stage, with finished product stage formulation samples, and developed a quantification method for MBN. Several authors have reported several methods for MBN quantification by spectrophotometric estimation (Morshedy et al, 2020; Papanna et al, 2018; Rao et al, 2017; Roopa et al, 2021). Few authors have reported a UV spectrophotometric method for bulk drug analysis (Ravisankar et al, 2016; Suresh et al, 2020) or LC/MS and thin‐layer chromatography methods for clinical analysis (Shah et al, 2019; Van Teijlingen et al, 2012).…”
Section: Introductionmentioning