2021 IEEE 3rd Global Conference on Life Sciences and Technologies (LifeTech) 2021
DOI: 10.1109/lifetech52111.2021.9391786
|View full text |Cite
|
Sign up to set email alerts
|

Validation of CW Doppler Radar Embedded Within Driving Seat For Heartbeat Detection Using NHA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…Locating the radar close to the heart usually leads to higher signal quality. In some systems, such as the PhysioChair [ 40 ], the stress assessment method [ 41 ], and the method for monitoring a driver’s heartbeat information [ 42 ], the radar is installed in the position of the seat back directly opposite to the chest, and obvious heartbeat signals can be seen in the chest movement waveform demodulated from radar echoes. A simple processing method like a bandpass filter is sufficient to extract heartbeat signals with high quality.…”
Section: Discussionmentioning
confidence: 99%
“…Locating the radar close to the heart usually leads to higher signal quality. In some systems, such as the PhysioChair [ 40 ], the stress assessment method [ 41 ], and the method for monitoring a driver’s heartbeat information [ 42 ], the radar is installed in the position of the seat back directly opposite to the chest, and obvious heartbeat signals can be seen in the chest movement waveform demodulated from radar echoes. A simple processing method like a bandpass filter is sufficient to extract heartbeat signals with high quality.…”
Section: Discussionmentioning
confidence: 99%
“…We have previously demonstrated that NHA can effectively suppress sidelobes and detect subtle heart rate signals hidden within respiratory signals [15], [38].…”
Section: ) Nhamentioning
confidence: 99%
“…The experimental setup included a 24-GHz 70mm-wide and 50-mm-long CW Doppler radar (Carea Corporation CRA-24 GHz). To measure the non-contact heart rates of automobile drivers, the Doppler radar has been installed either on the back of the seat [15], [38], [52] or directly on the seatbelt [18], and studies have been conducted to measure heart rate displacement mainly from chest circumference variation. Accordingly, we chose to install the radar behind the seat rather than in front to mitigate noise generated by the driver's movements.…”
Section: Experimental Conditions a Experimental Environment And Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…As well, beamforming imaging radar is applied to cancer diagnoses [ 18 , 19 , 20 ]. In the automotive industry, the radar function of monitoring respiration and heartbeat applies to occupant detection [ 21 , 22 , 23 , 24 , 25 ] and driver monitoring system [ 26 , 27 , 28 ]. Some companies already sell cars with occupancy detection radar.…”
Section: Introductionmentioning
confidence: 99%