2016
DOI: 10.1016/j.steroids.2016.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Validation of highly sensitive simultaneous targeted and untargeted analysis of keto-steroids by Girard P derivatization and stable isotope dilution-liquid chromatography-high resolution mass spectrometry

Abstract: A multiplexed quantitative method for the analysis of three major unconjugated steroids in human serum by stable isotope dilution liquid chromatography-high resolution mass spectrometry (LC-HRMS) was developed and validated on a Q. Exactive Plus hybrid quadrupole/Orbitrap mass spectrometer. This quantification utilized isotope dilution and Girard P derivatization on the keto-groups of testosterone (T), androstenedione (AD) and dehydroepiandrosterone (DHEA) to improve ionization efficiency using electrospray io… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
18
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 34 publications
3
18
0
Order By: Relevance
“…In an across-matrix comparison, standard curves constructed in water and charcoal stripped serum produced similar and parallel standard curves indicating no major matrix effects from meconium ( Figure 3 ). Inter- and intra-day validation (n=5) gave accuracy and precision below 15% CV except for AD which was below 25% due to low precision from one run (28). Lower precision for AD is in-line with previously reported findings for this analyte (31).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In an across-matrix comparison, standard curves constructed in water and charcoal stripped serum produced similar and parallel standard curves indicating no major matrix effects from meconium ( Figure 3 ). Inter- and intra-day validation (n=5) gave accuracy and precision below 15% CV except for AD which was below 25% due to low precision from one run (28). Lower precision for AD is in-line with previously reported findings for this analyte (31).…”
Section: Resultsmentioning
confidence: 99%
“…No certified reference material is available for any of the steroids examined here for meconium, and we did not have sufficient biospecimen to conduct comparisons in this study to RIA or other ligand binding assays for meconium. The assay used has been previously compared to the NIST Standard Reference Material (SRM) for hormones in serum and found to provide values within 5% of the reference method (28). …”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Corticosterone was measured by liquid chromatography-mass spectrometry using adaptation of previously published method for keto-steroids(Frey et al, 2016). Briefly, 20 μL of serum was extracted by addition of 20 μL of (100 pg/μL in methanol as an internal standard) 2 H 4 -corticosterone, 15 μL saturated NaCl, acidification with 5 μL 1N HCl, 0.5 mL methyl-tert-butyl-ether, and 80 μL water.…”
Section: 0 Methodsmentioning
confidence: 99%