2014
DOI: 10.1002/bmc.3349
|View full text |Cite
|
Sign up to set email alerts
|

Validation of HPLC‐UV method for determination of minor glycosides contained in Stevia rebaudiana Bertoni leaves

Abstract: Leaves of Stevia rebaudiana contain glycosides with sweetness and biological activity. However besides the major glycosides, there are other glycosides within extracts that may contribute to its activity, and therefore it is important to quantify them. In this work, an isocratic HPLC method was validated for determination of dulcoside A, steviolbioside, rebaudioside C and rebaudioside B. An HPLC method was performed using a C18 column (250 × 4.6 mm, particle size 5 µm) and a UV detector set at 210 nm. The mobi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2017
2017
2025
2025

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 24 publications
1
7
0
Order By: Relevance
“…The linearity response and linear regression equation for each glycoside is presented in Table 1. A good correlation coefficient and coefficient of determination was obtained as expected, given that the method used was previously validated (Aranda-González et al, 2014); however, they are presented to establish the conditions of quantification.…”
Section: Resultssupporting
confidence: 66%
See 2 more Smart Citations
“…The linearity response and linear regression equation for each glycoside is presented in Table 1. A good correlation coefficient and coefficient of determination was obtained as expected, given that the method used was previously validated (Aranda-González et al, 2014); however, they are presented to establish the conditions of quantification.…”
Section: Resultssupporting
confidence: 66%
“…Although there were no significant differences in the content, it was possible to quantify dulcoside A, rebaudioside D, and steviolbioside in the four drying methods, as previously published (Aranda-González et al, 2014).…”
Section: Resultsmentioning
confidence: 84%
See 1 more Smart Citation
“…It is noteworthy that the quantification of glycosides was obtained from a previously validated HPLC method, which chromatographic data and validation parameters can be consulted elsewhere. [22,23] In this regard, all steviol glycosides are at lower concentration than previously reported, [22,23] possibly attributed to a different batch. Comparing the varieties Morita II and Criolla, there are no differences in the content of minor glycosides, except for Rebaudioside B and Rebaudioside D; however, the most important difference are the content of Stevioside and Rebaudioside A. Morita II variety had higher content of total glycosides as compared to the Criolla variety (16.74 vs. 9.65 g/100 g) with a higher content of Rebaudioside A (4.5 times more).…”
Section: IIImentioning
confidence: 61%
“…Quantification of the steviol glycosides content was based on peak area, from linear regression curves of the standards. [22,23] …”
Section: Chromatographic Conditions and Quantification Of Steviol Glymentioning
confidence: 99%