2011
DOI: 10.1109/tec.2010.2087337
|View full text |Cite
|
Sign up to set email alerts
|

Validation of Single- and Multiple-Machine Equivalents for Modeling Wind Power Plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 97 publications
(18 citation statements)
references
References 3 publications
0
17
0
1
Order By: Relevance
“…Wind power plants can be modeled including an equivalent transformer connected to the collector bus by the cable systems modeled as a PI model. The model has been validated by verifying with actual measurement data in power flow analysis, stability and electromagnetic transient studies [14] [ 16]. Although these studies have done for wind power plants in the range of 50-300 MW, conducting this model in harmonic resonance study is still worth considering.…”
Section: Aggregate Modelmentioning
confidence: 99%
“…Wind power plants can be modeled including an equivalent transformer connected to the collector bus by the cable systems modeled as a PI model. The model has been validated by verifying with actual measurement data in power flow analysis, stability and electromagnetic transient studies [14] [ 16]. Although these studies have done for wind power plants in the range of 50-300 MW, conducting this model in harmonic resonance study is still worth considering.…”
Section: Aggregate Modelmentioning
confidence: 99%
“…4 se muestra la zona donde la máquina no debe desconectarse según lo que indica la norma usada El parque representado esta compuesto por 52 aerogeneradores con un equivalente de una sola máquina conectada a la barra 31. Las máquinas poseen un modelo genérico tipo 4 donde se realiza un equivalente en una sola máquina en el punto común de conexión [17]. Las turbinas eólicas operan a una capacidad del 100% entregando una potencia de 130 MW con un factor de potencia cercano a la unidad.…”
Section: Plantas Eólicasunclassified
“…Aggregated wind turbines in one wind power plant are represented by single machine equivalent system comprised of only one equivalent wind turbine, one equivalent collector system and actual station step-up and grounding transformers [5,6] . The interconnection transmission line, station transformers and plant-level reactive compensation should be represented explicitly, according to established network.…”
Section: Model Descriptionmentioning
confidence: 99%