1998
DOI: 10.1089/jam.1998.11.65
|View full text |Cite
|
Sign up to set email alerts
|

Variations in Predicted Regional Lung Deposition of Salbutamol Sulphate Between 19 Nebulizer Types

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
28
0
1

Year Published

2001
2001
2016
2016

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(30 citation statements)
references
References 26 publications
1
28
0
1
Order By: Relevance
“…For both pMDIs and DPIs, it is preferable to perform in vitro experiments in realistic or idealized mouth-throat geometries (21) in order to estimate in vivo lung doses for a given device/formulation combination. For nebulizers, where fine droplets are well entrained in the inhaled airflow, deposition correlations and models tend to be more reliable, (22) provided hygroscopic behavior of the nebulized aerosol is included in the model, or may be safely neglected. (23) Regional lung deposition Many inhaled therapies are developed under the assumption that, in addition to the total dose delivered to the lungs, the regional deposition pattern within the lungs is an important determinant of efficacy.…”
Section: Targeting Approachesmentioning
confidence: 99%
“…For both pMDIs and DPIs, it is preferable to perform in vitro experiments in realistic or idealized mouth-throat geometries (21) in order to estimate in vivo lung doses for a given device/formulation combination. For nebulizers, where fine droplets are well entrained in the inhaled airflow, deposition correlations and models tend to be more reliable, (22) provided hygroscopic behavior of the nebulized aerosol is included in the model, or may be safely neglected. (23) Regional lung deposition Many inhaled therapies are developed under the assumption that, in addition to the total dose delivered to the lungs, the regional deposition pattern within the lungs is an important determinant of efficacy.…”
Section: Targeting Approachesmentioning
confidence: 99%
“…Less affordable, but more compact, ultrasonic nebulizers find widespread use in many clinical settings. Finlay, Stapleton & Zuberbuhler (1998) compared various traditional nebulizers and found a large variation in the predicted lung dosage between the devices.…”
Section: Advances In Delivery Devicesmentioning
confidence: 99%
“…In situ measurement is especially useful in sizing volatile aerosols, where particle (droplet) sizes change with time [102,103] . However, because the PDPA measures particle sizes at a precise location in the fl ow, determined by the intersection of the two laser beams, it is important either to perform measurements at several locations across the fl ow or to choose one location for which measurements are representative of the overall aerosol size distribution.…”
Section: Inertial Impactorsmentioning
confidence: 99%
“…Where should the aerosol size distribution be measured, and what does the distribution represent? One approach is to measure droplet sizes as close to the mouthpiece of the delivery system as is possible [103,105] . The meaof HFA pMDIs may be found in Vervaet and Byron [112] and in Smyth [113] .…”
Section: Evaporation and Condensationmentioning
confidence: 99%
See 1 more Smart Citation