2008
DOI: 10.1109/lpt.2008.916947
|View full text |Cite
|
Sign up to set email alerts
|

VCSEL Optoelectronic Biosensor for Detection of Infectious Diseases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 11 publications
0
11
0
1
Order By: Relevance
“…Taking into consideration these limitations, new methodologies and devices aimed at dengue diagnosis have been reported over the past decades . These biosensors can be classified based on the types of physical transduction mechanism exploited: piezoelectric (quartz crystal microbalance), optical (surface plasmon resonance, , chemiluminescence, , magnetoresistance, fluorescence, photonic crystals , ), and electrochemical. For successful diagnosis of dengue infection in tropical and developing countries, a biosensor should gather the advantages of simplicity, economy, rapidity, and accuracy . These requirements have not been attained with any existing method, nor have any of the aforementioned studies demonstrated the detection of dengue infection in patient blood plasma.…”
mentioning
confidence: 99%
“…Taking into consideration these limitations, new methodologies and devices aimed at dengue diagnosis have been reported over the past decades . These biosensors can be classified based on the types of physical transduction mechanism exploited: piezoelectric (quartz crystal microbalance), optical (surface plasmon resonance, , chemiluminescence, , magnetoresistance, fluorescence, photonic crystals , ), and electrochemical. For successful diagnosis of dengue infection in tropical and developing countries, a biosensor should gather the advantages of simplicity, economy, rapidity, and accuracy . These requirements have not been attained with any existing method, nor have any of the aforementioned studies demonstrated the detection of dengue infection in patient blood plasma.…”
mentioning
confidence: 99%
“…为此, Brazaca 等 [72] 用聚丙烯生物脱离方法将核酸捕获探针固定在平 行 1D 光子晶体谐振器传感器表面, 可去除 98%的残基, 用多种模式检测登革热病毒. Huang 等 [73] 基于光子晶体 表面的感测能力, 发展了可调谐的垂直腔表面发射激光 器(VCSEL), 用于登革热 IgG 抗体的检测, 尽管该方法 比 ELISA 方法灵敏度高, 但仍有假阳性.…”
Section: 光子晶体生物传感器unclassified
“…Only one wavelength sweep is sufficient to test the optical properties of the common optical components. In the biosensor application, the spectral shift of the sensor's optical properties, such as transmittance or reflectance is measured [15,21]. The optical properties of the sample must be measured several times.…”
Section: Orrb Readermentioning