Very fast transient overvoltage calculation and evaluation for 500‐kV gas insulated substation power substation with double circuit and long gas insulated substation busbar

Abstract: The operation of disconnectors in gas insulated substation (GIS) or power plant will produce very fast transient overvoltage (VFTO), which is considered to have serious harm to transformer longitudinal insulation and other high‐voltage equipment insulation. VFTO may also lead to secondary circuit failure. In this paper, the holistic modelling of 500 kV GIS step‐up substation equipment with a double circuit and long GIS busbar in a coastal power plant is established using Electromagnetic Transient Program (EMTP… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…Overhead lines are widely used in power transmission and distribution because they are relatively inexpensive and have lower electrical losses compared to underground cables. However, they can be vulnerable to weather-related disruptions such as high winds, lightning, and ice accumulation [11][12][13][15][16][17][18][19][20].…”
Section: Overhead Linementioning
confidence: 99%
“…Overhead lines are widely used in power transmission and distribution because they are relatively inexpensive and have lower electrical losses compared to underground cables. However, they can be vulnerable to weather-related disruptions such as high winds, lightning, and ice accumulation [11][12][13][15][16][17][18][19][20].…”
Section: Overhead Linementioning
confidence: 99%
“…However, this method relies on the physical modeling of hybrid reactive power compensation devices, making it difficult to widely apply to different scenarios. Based on EMTP, a GIS bus, and step-up substation equipment model for a 500 kV double circuit line is constructed [22] . Based on this, the VFTO waveforms that may occur during various operations are calculated by analyzing the oscillation and frequency characteristics of the waveform on its electrical characteristics and the impact withstand voltage of the lightning arrester.…”
Section: Introductionmentioning
confidence: 99%