2020
DOI: 10.3390/app10051777
|View full text |Cite
|
Sign up to set email alerts
|

Virtual PLC Lab Enabled Physical Layer Improvement Proposals for PRIME and G3-PLC Standards

Abstract: Narrowband (NB) powerline communication (PLC) is extensively adopted by utilities for the communication in advanced metering infrastructure (AMI) systems. PLC technology needs to overcome channel disturbances present in certain grid segments. This study analyzes improvement proposals of the physical layer of the main narrowband PLC technologies approved by international communication organizations that are currently deployed in Europe: Powerline Intelligent Metering Evolution (PRIME) 1.3.6, PRIME 1.4, and G3-P… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…Nevertheless, [36] addresses such an interesting application for DSOs as the remote and massive upgrade of firmware in PRIME networks. More recently, references [37,38] stand out as two innovative approaches for simulating the PHY layer of NB-PLC technologies. The authors of [37] propose a new methodology for network scale simulation based on directly implementing an OFDM modulator in EMTP-ATP (electromagnetic transients programme-alternative transients programme).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless, [36] addresses such an interesting application for DSOs as the remote and massive upgrade of firmware in PRIME networks. More recently, references [37,38] stand out as two innovative approaches for simulating the PHY layer of NB-PLC technologies. The authors of [37] propose a new methodology for network scale simulation based on directly implementing an OFDM modulator in EMTP-ATP (electromagnetic transients programme-alternative transients programme).…”
Section: Discussionmentioning
confidence: 99%
“…By configuring different OFDM parameters, both PRIME and G3-PLC are considered, observing that they are significantly affected in medium-voltage (MV) power line channels. Reference [38] presents an analysis that focuses on how the use of different error correction codes, mechanisms for suppressing noisy intercarriers, and adjusting the equalization curve affect the performance of PRIME and G3-PLC by using an innovative ad hoc virtual PLC lab, developed by the authors, which allows for replicable, fully automated, and cost-effective tests.…”
Section: Discussionmentioning
confidence: 99%