2012
DOI: 10.1371/journal.pone.0049094
|View full text |Cite
|
Sign up to set email alerts
|

Virtual Touch Tissue Quantification of Acoustic Radiation Force Impulse: A New Ultrasound Elastic Imaging in the Diagnosis of Thyroid Nodules

Abstract: ObjectiveVirtual touch tissue quantification (VTQ) of acoustic radiation force impulse (ARFI) is a new quantitative technique to measure tissue stiffness. The study was aimed to assess the usefulness of VTQ in the diagnosis of thyroid nodules.Methods173 pathologically proven thyroid nodules in 142 patients were included and all were examined by conventional ultrasound (US), conventional elasticity imaging (EI) and VTQ of ARFI. The tissue stiffness for VTQ was expressed as shear wave velocity (SWV) (m/s). Recei… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
146
1
3

Year Published

2017
2017
2018
2018

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 110 publications
(160 citation statements)
references
References 28 publications
10
146
1
3
Order By: Relevance
“…In other words, both extremely hard and soft tissue can be shown as "X.XX m/s". In most previous study, the value of "X.XX m/s" is allocated to be 0 m/s or 9 m/s with 0 m/s corresponding cystic portion and 9 m/s corresponding solid portion [20]. Considering that 0 and 9 were the extreme values in Vs range, and frequent appearance would lead the Vs group to be skewness distribution, in present study, we excluded the thyroid which Vs displayed as "X.XX m/s", thus t test could be used to compare ARFI-measurements in benign thyroid nodules and malignant thyroid nodules.…”
Section: Discussionmentioning
confidence: 95%
See 2 more Smart Citations
“…In other words, both extremely hard and soft tissue can be shown as "X.XX m/s". In most previous study, the value of "X.XX m/s" is allocated to be 0 m/s or 9 m/s with 0 m/s corresponding cystic portion and 9 m/s corresponding solid portion [20]. Considering that 0 and 9 were the extreme values in Vs range, and frequent appearance would lead the Vs group to be skewness distribution, in present study, we excluded the thyroid which Vs displayed as "X.XX m/s", thus t test could be used to compare ARFI-measurements in benign thyroid nodules and malignant thyroid nodules.…”
Section: Discussionmentioning
confidence: 95%
“…Tissue within a "measuring box" (6 × 5 mm) is mechanically stimulated using short-duration (262 µs) acoustic pulses [8]. The stiffer (nonelastic) the tissue through which the wave passes, the greater the shear velocity is.…”
Section: Arfimentioning
confidence: 99%
See 1 more Smart Citation
“…Для оценки возможности использовании эласто-метрии в целях диагностики субклинических метаста-зов был проведен статистический анализ полученных (27,3) Сокращения: pN0 и pN+ -соответственно отсутствие и наличие метастаза по данным гистологического исследования.…”
Section: эффективность узи с использованием эластоме-трии и эластографииunclassified
“…Кроме того, необходимы дополнительные исследова-ния для установления пороговых величин эластоме-трии, а также уточнение эластографических параме-тров диагностики субклинических метастазов. Пороговая величина для дифференциальной диагно-стики между непораженными и пораженными опухо-лью лимфатическими узлами, по данным различных исследований, колеблется в пределах 1,5-4,82 м / с [20,[24][25][26][27][28].…”
unclassified