Visual versus computerised assessment of left ventricular function from cinéangiography

Abstract: Visual assessment of left ventricular function from cinéangiography was compared with computerised assessment in 48 randomly selected cinéangiograms. The parameters compared included end-diastolic volume, end-systolic volume, stroke volume, ejection fraction and left ventricular output. There was poor agreement between visual and calculated values for end-diastolic volume, stroke volume and left ventricular output, but good agreement for ejection fraction and moderately good agreement for end-systolic volumes.… Show more