Abstract: In modern anesthesia, multiple medical devices are used simultaneously to comprehensively monitor real-time vital signs to optimize patient care and improve surgical outcomes. However, interpreting the dynamic changes of time-series biosignals and their correlations is a difficult task even for experienced anesthesiologists. Recent advanced machine learning technologies have shown promising results in biosignal analysis, however, research and development in this area is relatively slow due to the lack of biosi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
41
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 69 publications
(41 citation statements)
references
References 21 publications
0
41
0
Order By: Relevance
“…This limitation makes the analysis that rely on the synchronization of ECG, PPG or ABP waveforms (e.g., extraction of the pulse arrival time), unreliable. Unlike the MIMIC database, however, waveform synchronization is secured in the VitalDB dataset ( 33 ). Therefore, we suggest using segments from VitalDB for the analysis requiring precise inter-signal alignment among ECG, PPG or ABP.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…This limitation makes the analysis that rely on the synchronization of ECG, PPG or ABP waveforms (e.g., extraction of the pulse arrival time), unreliable. Unlike the MIMIC database, however, waveform synchronization is secured in the VitalDB dataset ( 33 ). Therefore, we suggest using segments from VitalDB for the analysis requiring precise inter-signal alignment among ECG, PPG or ABP.…”
Section: Discussionmentioning
confidence: 99%
“…In the remaining databases, only the MIMIC-II and MIMIC-III waveform databases matched subsets and the VitalDB database contain subject identification and demographic information. Since the MIMIC-III matched subset is a superset of the MIMIC-II matched subset ( 32 ), the MIMIC-III matched subset ( 32 ) and the VitalDB database ( 33 , 37 ) were selected as the original sources.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Harnessing the intraoperative physiologic data, including waveforms, will allow gaining further insights. Recently, a large vital signs repository of perioperative patient data became publicly available [41]. This dataset contains high-resolution multiparameter data from 6388 cases, including waveform and numeric data of 196 intraoperative monitoring parameters, 73 perioperative clinical parameters, and 34 time-series laboratory results.…”
Section: Future Directionsmentioning
confidence: 99%