2007
DOI: 10.1016/j.jhsa.2007.04.016
|View full text |Cite
|
Sign up to set email alerts
|

Volar Versus Dorsal Fixed-Angle Fixation of Dorsally Unstable Extra-Articular Distal Radius Fractures: A Biomechanic Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
0
5

Year Published

2008
2008
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(50 citation statements)
references
References 26 publications
0
45
0
5
Order By: Relevance
“…There is a large volume of literature on clinical performance (functional scores and radiological outcomes) of many modalities, either on their own or in comparison with one or more of others [13]- [19]. This has led to identification and discussion of shortcomings and complications of many modalities [17]. For example, for a VLP system, a) its shortcomings include high possibility for prominence if applied distally and possibility for irritation of tendon(s) [14]; and b) among its complications are carpal tunnel syndrome, peripheral nerve palsy, extensor tenosynovitis, and rupture of tendon(s) [17] [19].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…There is a large volume of literature on clinical performance (functional scores and radiological outcomes) of many modalities, either on their own or in comparison with one or more of others [13]- [19]. This has led to identification and discussion of shortcomings and complications of many modalities [17]. For example, for a VLP system, a) its shortcomings include high possibility for prominence if applied distally and possibility for irritation of tendon(s) [14]; and b) among its complications are carpal tunnel syndrome, peripheral nerve palsy, extensor tenosynovitis, and rupture of tendon(s) [17] [19].…”
Section: Introductionmentioning
confidence: 99%
“…This has led to identification and discussion of shortcomings and complications of many modalities [17]. For example, for a VLP system, a) its shortcomings include high possibility for prominence if applied distally and possibility for irritation of tendon(s) [14]; and b) among its complications are carpal tunnel syndrome, peripheral nerve palsy, extensor tenosynovitis, and rupture of tendon(s) [17] [19]. Thus, there is scope for modifications to current modalities and/or introduction of new ones.…”
Section: Introductionmentioning
confidence: 99%
“…Questa rapida ripresa funzionale dei polsi operati ci sembra quindi il maggiore vantaggio del DNP rispetto alle placche a stabilità angolare, applicate sia volarmente sia dorsalmente, con tecniche più invasive. La stabilità della sintesi con il DNP è confermata anche da un recente studio biomeccanico di confronto con due tipi di placche a stabilità angolare [5]. Si può affermare perciò che il DNP è un valido sistema di fissazione a stabilità angolare per le fratture extra-articolari instabili del radio distale, applicabile con un accesso chirurgico poco invasivo.…”
Section: Risultati E Discussioneunclassified
“…Specimens were loaded in axial compression similar to previously published studies. 12,16,17 We applied a 10 N preload before testing. Axial compression was delivered at 1 N/s over 3 cycles from 20 N to 100 N to determine axial stiffness.…”
Section: Methodsmentioning
confidence: 99%