2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES) 2016
DOI: 10.1109/icpeices.2016.7853132
|View full text |Cite
|
Sign up to set email alerts
|

Voltage stability assessment in radial distribution system by line stability indicator (LSI) and its improvement using SVC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 9 publications
0
9
0
Order By: Relevance
“…Equation [9] is very important as it gives us the relationship between the amount of reactive power injected at any particular or set of buses and the change in voltage at all buses. Let…”
Section: Derivation Of L-index Sensitivity Matrixmentioning
confidence: 99%
See 1 more Smart Citation
“…Equation [9] is very important as it gives us the relationship between the amount of reactive power injected at any particular or set of buses and the change in voltage at all buses. Let…”
Section: Derivation Of L-index Sensitivity Matrixmentioning
confidence: 99%
“…L-Index Sensitivities (Lq) which presents the information of the modification in value of L-Index with change in reactive power injection has been suggested. In reference (9), voltage stability assessment in radial distribution systems by proposing a new voltage stability index named Line Stability Index (LSI). Line stability index predicts the line which is more prone to voltage instability.…”
Section: Introductionmentioning
confidence: 99%
“…Considering Advanced Metering Infrastructure (AMI) like Phasor Measuring Unit (PMU) these two indices are more suitable for Smart Grid (SG) environment. Line Stability Index (LSI) is introduced using load angles, branch parameters and current and reactive power of receiving node [11]. Importantly, this index seems to be independent of voltage magnitudes but required indirectly while calculating the branch current.…”
Section: Introductionmentioning
confidence: 99%
“…Power quality is always the top priority for the electrical utility to look on providing a continuous supply to their customers. The integration of distributed generators in the distribution network is increasing day by day [1] due to the protection of the environment from harmful emissions, technological advancement, energy crisis, power outages, technical issues, and economic incentives [2]. The intermittent nature of renewable energy sources will introduce many challenges to the power quality of the electricity supply [3].…”
Section: Introductionmentioning
confidence: 99%
“…Voltage stability is essentially related to the reactive power balance [1], so by controlling reactive power between leading and lagging power factor can maintain the voltage within the acceptable voltage range and improve the reliability of the system. The conventional method in controlling the reactive power where power factor correction was fixed by the integration of fixed capacitors proving reactive power supply.…”
Section: Introductionmentioning
confidence: 99%